Home > GENERAL > GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

ProductDisplayLayout  
BATTERY PLACEMENT  
PAIRINGTHEROOMTHERMOSTATANDTHERECEIVER  
ENGLISH  
Primarily press the sync button of the Receiver for 2 seconds and see blinking  
greenlight oftheReceiver.  
7
8
1
2
While yourdeviceis turned off, pressand hold the"On/Off" button for 3 seconds.  
DIGITAL ROOM THERMOSTAT  
Pressthebutton until the“  
” menu appears.  
Press the “Up” or “Down” button of your Room Thermostat while the LED is  
flashing green.  
generallife.com.tr  
9
3
10  
11  
Ifthepairing issuccessful, thegreenashing LEDon theReceiverwillbe steady.  
Receiverand Room Thermostathavebeen pairedto each other.  
4
5
6
ARUNA 300S RF USER MANUAL  
ROOMTHERMOSTATTEMPERATURECALIBRATION  
Temperature sensors which are used in Room Thermostats are highly sensitive.  
You may need to calibrate your Room Thermostat if you would like to get the same  
temperaturevalueswithother thermometersin yourliving space.  
GENERALSPECIFICATIONS  
1
2
3
4
5
6
7
8
9
Hour Indicator  
Press the screwdriver forward from the space at the bottom of the Room  
Thermostat, bend the tabs and separate the front cover. Insert 2 new AAA alkaline  
batteries in the battery housing with the correct battery direction. Replace both  
batteries at the same time. Align the front part of your Room Thermostat with  
corresponding slot on the back, and then push gently until the thermostat snaps  
into place.  
ARUNA 300S RF is a wireless room thermostat. The user can get more comfortable  
and economic heating/cooling by adjusting the room thermostat with the required  
temperature.  
While yourdeviceis turned off, pressand hold theOn/Off“ button for 3 seconds.  
Press the "On/Off" button until the “ ” menu appears. In order to see the  
Room Temperature  
Economy Mode  
Comfort Mode  
desired temperature, set the temperature difference by pressing the  
Dailyand WeeklyProgramming  
“Temperature Adjustment Buttons”. This value can be arranged between “-8° C"  
Holiday Mode  
Weekly Program Mode  
Day Indicator  
DifferentMode Options (Comfort, Economy, Holiday)  
and “+8° C".  
Heating Calibration  
ON/OFFControl  
WirelessConnection  
Alkaline Battery  
In order to save the settings and exit, press the "On/Off" button until the device  
turns off.  
Low Battery Warning: When the “  
” icon appears on the screen, it means “low  
Heating/Cooling Option  
TPIAlgorithm  
Battery Indicator  
Set Temperature  
Heating Indicator  
battery warning”. It is recommended to replace the batteries when this warning  
appears.  
PreciseTemperatureMeasurement  
Note:Recommended temperaturecalibration is “0.0°C”.  
Warning: When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would be out of  
warranty. Pleasethrowyourdead batteriesinto thewastebin for batteries.  
ARUNA 300SRFand EQUIPMENTS  
FACTORY SETTINGS RESET  
10  
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Cooling Indicator  
You can reset your Room Thermostat to its default factory settings. This operation  
resets the mode temperature values, calibration setting and heating/cooling  
modes to factory setting. In orderto resetyourRoom Thermostatto factory setting:  
ARUNA 300S RF  
Room Thermostat  
Holder  
11  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
RECEIVERPLACEMENT  
While yourdeviceis turned off, pressand hold theOn/Off” button for 3 seconds.  
PresstheOn/Off” button untilthe“ ” menu appears.  
While in the “ ” menu, select the “ ” option by using the “Up” or “Down”  
buttons and presstheOn/Off” button.  
Your devicewillbe turned off and resetto factory settings.  
The important things to note for the Receiver placement are  
avoiding physical contact between the Receiver and  
heating/cooling unit, and protecting it against materials  
such asliquid, dust etc.  
RECEIVER  
1-Manual Operation Button: Deactivates the  
Receiver and allows you to use heating/cooling  
unit manually.  
Dowels and Screws  
Receiver  
1
2
3
DAY ANDHOURSETTINGS  
2-Pairing Button: Allows pairing the Receiver  
with the Room Thermostat.  
3-Receiver LED Light  
4-Receiver Power Cable Input  
5-Heating/Cooling Unit Connection Cable Input  
The devices should be placed in order to minimize the damage to the received and  
transmittedsignals bypayingattentiontothefollowingpoints;  
While your Room Thermostat is on, keep pressing the “Weekly Programbutton  
for 3 seconds.  
The devicesshould not be mounted on metalsurfaces.  
At the first screen that appears, hour part will be blinking. You may set the time  
withtheUpandDownbuttons.  
The devices should not be installed close to electrical cables and electronic  
equipment such ascomputers and televisionunits.  
After setting the time, the “Heating & Cooling Optionbutton needs to be pressed  
once. For minute setting, minute part will be blinking. You mayset the minute with  
theUpand Downbuttons.  
The devices should not be installed near large metal structures or other building  
materialsusing finemetalmeshes such asspecialglass or specialconcrete.  
Distance between the Room Thermostat and the Receiver should not exceed 20  
metersor 2 floors.  
TECHNICALDATA  
Room Thermostat  
After setting the minute, the “Heating & Cooling Optionbutton needs to be  
pressedonce to setthedayof theweek.  
Dimensions  
Operating Current  
85mm / 125mm / 20mm  
3V DC (2 x AAA alkaline battery)  
0.1oC  
Receivermust be installed atleast50cmawayfromtheheating/cooling unit.  
Mondayhas setastherstdayof theweekand indicated withnumber1".  
Numbers indicate the following days respectively 2-Tuesday, 3-Wednesday, 4-  
Thursday, 5-Friday, 6-Saturdayand 7-Sunday  
4
5
RECEIVERLEDDESCRIPTIONS  
Temperature Measurement Accuracy  
Operating Temperature Range  
Battery Life  
(5oC) – (30oC)  
RECEIVERSETUP  
Steady Red  
Receiver has power but Receiver and Room Thermostat  
First, shut down your heating/cooling unit and your heating/cooling unit's power  
sourcewithallelectricalcurrent(fuse, socketetc.)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
When setting is done, you may exit by pressing the “Weekly Program” button for 3  
seconds.  
are not paired.  
Operating Temperature  
Storage Temperature  
Blinking Green  
Steady Green  
Waiting for pairing signal from the Room Thermostat.  
Receiver and Room Thermostat are paired.  
Heating/cooling unit is not operating.  
As shown in the connection diagram, connect one end of the heating/cooling unit  
connection cableto theCOMand theother to theNO input of theReceiver.  
Connect the other ends of the cable -which you connected to the Receiver- to  
room thermostat connection terminal as shown in your heating/cooling unit's  
user manual.  
MODESETTING  
MODES  
3 Short Orange Blinking Operate the heating/cooling unit signal has reached to  
the Receiver.  
Receiver  
Dimensions  
Operating Current  
Relay NO Switching Current  
90mm / 90mm / 25mm  
230V AC  
Steady Orange  
Heating/cooling unit is operating.  
You must first connect the Receiver power cable to the Receiver and then to the  
fuse which theheating/cooling unit is connected.  
PRESET MODES  
WEEKLY  
PROGRAM  
MODE  
MANUAL MODE  
3 Short Green Blinking  
Shut the heating/cooling unit down signal has reached  
to the Receiver.  
7A (240VAC – Resistive Load)  
10A (120VAC – Resistive Load)  
(-20oC) – (+60oC)  
After completing the cable connection process, firstly turn on your fuse and then  
yourheating/cooling unit.  
Blinking Orange  
Blinking Red  
Heating/Cooling unit operates in manual mode.  
Receiver did not get any signal from the Room  
Thermostat for 22 minutes or longer.  
Heating/cooling unit has shut down.  
Storage Temperature  
Comfort  
Mode  
Economy  
Mode  
Holiday  
Mode  
By pressing the Receiver's manual usage button for 2 seconds, you should see  
the Orange Light blinking on the Receiver. In this way, after making sure that the  
heating/cooling unit is operating, press the same button again for 2 seconds and  
seethattheOrange LEDturns off.  
ROOMTHERMOSTAT  
ButtonFunctions  
Your Room Thermostat has 5 different modes. 3 of them (Comfort, Economy and  
Holiday Mode) are preset modes. Other modes are manual mode and weekly  
programmode.  
ROOMTHERMOSTATPLACEMENT  
Room Thermostat needs to be placed in the room which is used most frequently.  
For instance; living room or lounge. Placing the Room Thermostat in a spot that  
have air circulation like entrance of a room or side of window should be avoided.  
Also anywhere close to heating/cooling units such as radiator, stove and spots  
which get direct sun lights would not be suitable. Room Thermostat needs to be  
located above the floor 150 cm height. Few trials may be made to find the most  
convenientspot.  
Setup theRoom Thermostatto pair theReceiverwiththeRoom Thermostat.  
In preset modes, temperature values are based on user's choices which have been  
set in the beginning. Manual mode allows the Room Thermostat to operate within  
the temperature which is required and set directly by user. Weekly Program mode  
continues to workaccordingto theweeklyschedule determined bytheuser.  
In orderto change thetemperaturevaluesof presetmodes:  
RECEIVERWIRINGDIAGRAM  
AC  
COM  
NO  
(230V)  
Press and hold the “Mode” button for 3 seconds while your Room Thermostat is  
on.  
Comfort Mode temperature value will appear. You may adjust the temperature  
valueof Comfort Mode bypressingthe“Up” and “Downbuttons.  
When setting is done, you may adjust the temperature value of Economy Mode  
withthe“Up” and “Downbuttons bypressingtheModebutton again.  
You mayexitthesettingscreenbypressingtheModebutton 3 seconds.  
In orderto change the manual mode temperature, pressthe “Up” or “Downbutton  
while in the main screen. The Room Thermostat will switch to Manual Mode once  
pressedthe“Up” or “Downbutton.  
1
4
2
3
5
6
min. 20 cm  
1
2
3
4
5
6
On/Off Button  
Heating & Cooling Option  
Weekly Program Button  
HEATING/COOLING UNIT  
Temperature Adjustment Button (To Decrease)  
Temperature Adjustment Button (To Increase)  
Mode Button  
Warning!  
You maypresstheModebutton to switchto theother modes.  
Operations within the heating / cooling unit or the electrical installation must be  
carriedout byprofessionally qualified persons.  
1
2
3
4
GeneralDetails
NameGENERAL ARUNA 300S RF Digital Room Thermostat User Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size2.18 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 220 RF Digital Room Thermostat User Manual
GENERAL MITRA 220 RF Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
Get the free PDF manual for the GENERAL ARUNA 300S RF Digital Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Product display layout Battery placement Pairing the room thermostat and the receiver Press the sync button of the receiver for 2 seconds to see the blinking green light. If the pairing is successful, the green flashing LED on the receiver will be steady. Temperature sensors used in room thermostats are highly sensitive. You may need to calibrate your room thermostat to match other thermometers in your living space. ARUNA 300S RF is a wireless room thermostat that allows for comfortable and economic heating/cooling. The devices should not be installed close to electrical cables and electronic equipment. Room thermostat needs to be placed in the room that is used most frequently, avoiding areas with direct sunlight or near heating/cooling units.
  • Page 2: You may set the operating schedule of your room thermostat with a weekly program. The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years. Your room thermostat takes the average room temperature of the last 40 seconds as a basis. With the TPI algorithm, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Seven different temperature values can be set for each day in weekly programming. To set the weekly schedule, press and hold the “Weekly Program” button for 3 seconds while your room thermostat is on. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company. Malfunctions resulting from the use of devices contrary to the matters stated in the user manual are not covered by the warranty. The customer can make complaints and appeals to consumer courts or consumer arbitration committees. The warranty document must be kept by the customer during the warranty period.