FURRION FACW10ESSA-BL Standard Single Zone Wall Thermostat User Guide
See the “DIP Switch Settings” section in your air
conditioner instruction manual. Only activate the heat
mode(s) for the zone controller intended to operate the
heating function.
OPERATION
SPECIFICATIONS
Your Furrion wall thermostat has been preprogrammed
with factory default settings. Review the settings below and
adjust to your comfort level.
DC Input Power
Power Consumption
Baud Rate
DC 12V
<0.5W
Set the Temperature
9600bps
Factory Settings
The temperature set-point ranges from 60°F~86°F
(16°C~30°C).
Dimension
3 x 3 x 15/16” (75 x 75 x 22.5mm)
2.12oz. / 60g
12 o’clock
Heating
Cooling
Fan Speed
Mode
68°F / 20°C
72°F / 22°C
AUTO
Weight
1. Press the button to switch to desired mode.
LCD Viewing angle
2. Press or button to increase or decrease the
temperature set-point to your comfort level.
COOL
NOTE: The temperature set-point is not available in FAN mode.
Turn On/Off the Thermostat
Set the Fan Speed
To turn on, press and hold the button for 3 seconds to
turn on the thermostat. To turn off, press and hold button
for 3 seconds to turn off the thermostat.
1. Press the button to switch to your desired mode.
2. Press the FAN button to select the fan speed. The
available fan setting under each mode are as following:
Change the Temperature Format
Mode
Cool
Heat
Fan
Fan Speed
Low/High/Auto
Low/High/Auto/Off
Low/High
Press both the or buttons for 3 seconds to toggle the
temperature format between Centigrade and Fahrenheit.
NOTE: °F indicates Fahrenheit and °C indicates
Centigrade.
Dry
/
Change the Operating Mode
When Auto mode is selected, the fan will operate in High or Low
speed automatically by detecting the temperature difference
between the set-point and the room. When the set-point
temperature is reached, the fan will turn off after 30 seconds.
After the thermostat has been turned on, press the
button to toggle through COOL, HEAT, FAN and DRY
modes. The activated mode icon and temperature set-point
will be displayed on the LCD. The mode will be selected
automatically after 2 seconds without any operation.
LCD ERROR CODE
NOTE: If connected to a Furrion multi-zone control box
(FACC12ZA-BL or FACC12HA-BL), the furnace and/or
heatstrip DIP switches in the air conditioner control box
must be enabled:
The following error code will be displayed on the LCD when
the system detects one of the following faults has occurred.
LCD Error Code
–
–
–
Furnace ON, Heatstrip OFF - Furnace heat only, HEAT
F will be displayed on LCD after selected.
Control box indoor temperature sensor out of order.
System will shut down.
Furrion Innovation Center & Institute of Technology
E1
Heatstrip ON, Furnace OFF - Heatstrip heat only, HEAT
H will be displayed on LCD after selected.
● 52567 Independence Ct., Elkhart, IN 46514, USA
● Toll free:1-800-789-3341 ● Email: support@furrion.com
Evaporator temperature sensor out of order. System will
shut down.
E2
Furnace ON, Heatstrip ON - Furnace and heatstrip
heat, default is furnace heat mode (HEAT F), press the
button to switch to heatstrip heat mode (HEAT H).
©2007-2021 Furrion Ltd. Furrion® and the Furrion logo are trademarks
licensed for use by Furrion Ltd. and registered in the U.S. and other
countries.
Loss of communication between the thermostat and
control box. System will shut down.
E3
Thermostat indoor temperature sensor out of order.
System will shut down.
–
Furnace OFF, Heatstrip OFF - The heat mode is
disabled.
E6
FURRION.COM
Insufficient low level of +12V power supply. System will
shut down.
lo
IG-FHA00033 V1.0
| General | Details |
|---|---|
| Name | FURRION FACW10ESSA-BL Standard Single Zone Wall Thermostat User Guide |
| Make | FURRION |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.21 MB |

FURRION FACW12ZA-BL Multi Zone Wall Thermostat Instruction Manual