Informa�on & Technical Data
Power Supply:95 ~240 VAC, 50~60Hz
Current Load: 16A 3000W(electric hea�ng)
20A 4000W (electric hea�ng)
Sensor: NTC3950, 10K
Accuracy: 1°C
Set Temp. Range: 5-35°C
Room Temp. Range: 5-70°C
Display Temp. Range: 5 ~ 70°C
Ambient Temp.: 0~ 45°C
Ambient Humidity:
5 ~ 95 % RH (Non Condensing)
Storage Temp.:-5~ 45°C
Power Consump�on: <1. 5W
Timing Error: < 1%
Shell M aterial: PC +ABS ( Fireproof),PMMA
Installa�on Box:
86 * 86mm Square or European 60mm Round Box
Wire Terminals: Wire 2 x 1.5 mm2 or 1 x 2.5 mm2
Protec�on Class: IP20
Bu�ons: Knob + touch bu�on
Installa�on
Your thermostat is suitable for installa�on within a standard 86mm pa�ress box or European 60mm pa�ress box.
4. Installa�on completed
1. Accurately connect the power cable
2. Fix the moun�ng plate on the casse�e
with a screwdriver through two screws.
3. Hang the control panel onto the
moun�ng plate
to the power terminal box.
During Power On
Opera�on
1.Power On/off: Press the knob to turn the thermostat on/off.
Press the icon “ ” again, the temperature se�ng will flash, set the temperature
turning the knob;This completes the se�ng of periods1.
In the same way, complete the se�ngs of periods2, 3, 4,5and 6.Press the icon “
2.Manual & Programmable
Touch
”
to change between manual mode
and programme mode
.
once more to enter the Saturday schedule se�ngs (you will see the ⑥ of the screen).
Repeat the above process to set the period and temp. and ⑦ schedule.
Press the icon “ ” once more to confirm and exit.
In manual mode, will show on the display,
In programmable mode, will show on the display.
3.Se�ng Temperature
In the programming mode, the temperature se�ng and �me se�ng will be locked.
If the user wants to adjust, he must first adjust the thermostat to manual mode by
pressing the“ ”key.
Default se�ngs for program schedule
M ON. -FRI.
SAT.
SUN.
Time
(①②③④⑤ shows on scteen)
(⑥ shows on scteen)
(⑦ shows on scteen)
display
In the manual mode, pthe desired temperature can be set by turning the knob.
TIM E
TEM P.
20
ON TIM E
6:00~8:00
TEM P.
ON TIM E
6:00~8:00
TEM P.
4.Adjus�ng/Se�ng the Clock
Press“ ”to set minute, hour and weekday. and adjust the values by turning the knob.
Press “ ”once more to confirm and exit.
Period
Period
Period
Period
Period
Period
1
6:00~8:00
20
20
20
20
20
15
20
20
20
20
20
15
2
3
4
5
6
8:00~11:30
11:30~13:30
13:30~17:00
17:00~22:00
22:00~6:00
15
8:00~11:30
11:30~13:00
13:30~17:00
17:00~22:00
22:00~6:00
8:00~11:30
11:30~13:00
13:30~17:00
17:00~22:00
22:00~6:00
15
5.Locking your Thermostat
15
Press and hold the“ ”and“ ”for 5 seconds to lock/unlock your thermostat.
In item 3 of high senior op�ons, you can select full lock or half lock.
22
15
6.Adjus�ng/Se�ng the Programmable Schedules
Press icon“ ” four �mes in a row. You can see " ① ② ③ ④ ⑤ " and“ ”, a
nd the minutes of �me are flashing.
A separate schedule may be set for weekdays (Mon – Fri) and for weekends (Sat or Sun).
7.Checking the Temperature of Floor Sensor
Press and hold the“ ” arrow for 5 seconds to display the temp. of floor sensor. If no
external sensor is connected, the thermostat will display "Er".Note: Do not use third-
party external sensors, the temperature will be incorrect.
Turning the knob to set the minutes;
Press the icon “ ” again, the hour of the �me will flash, set the hour by turning
the knob;
8.Se�ng the Func�ons and Op�ons
During power off, Press and hold “ ”and “ ” for 8 sec. in the order to reach system func�on. Then press “ ” to scroll through the available func�ons,and use turning the knob
to change the available op�ons. All se�ngs are confirmed automa�cally.
Code
Function
Setting and options
Default
Code
Function
Setting and options
Default
1
Temperature compensation
-9 to 9 ℃
-3
9
High temp. protection setting. 25-70℃
45
Daytime display brightness
When set to 0, the device will run for 10
seconds after inactivity.
2
3
Deadzone Temp.
Button Locking
1-5℃
01
01
10
03
(6:00-22:00)
0-8
Brightness display brightness
The screen will go completely off with no
display.
00:All buttons are locked except power button.
01:All buttons are locked.
11
12
13
01
1
(22:00-06:00)
Screen line standby brightness 1-5
Power collection_x0002_working
In: Internal Sensor(to control the temp.)
Ou: External Sensor (to control the temp.)
AL: Internal& External Sensor (Internal sensor to
control the temp., external sensor to limit the
temp.)
4
Sensor typer
AL
0:24V,1:100V, 2:110V, 3:120V, 4:220V, 5:230V
4
voltage
Month
Days
14
15
Show only
Show only
5
6
Min.Set Temp.
Max.Set Temp.
5-15℃
05
35
15-45℃
00: No factory reset;
01: Factory reset
00:Display set Temp. and Room Temp.
01:Only display set Temp.
0-10℃
16
17
Reset
00
7
8
Temp. display
00
00
Low temp. protection setting.
Version number
U2
| General | Details |
|---|---|
| Name | expert4house BHT-18 AI Knob Thermostat User Guide |
| Make | EXPERT4HOUSE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.44 MB |

expert4house BHT-006 Series Thermostat Instruction Manual

expert4house BHT-003 Series Zigbee Thermostat User Guide

Expert4house BHT-9000 Smart Knob Thermostat User Guide

expert4house BHT-12 Smart Thermostat User Manual

expert4house BHT-2000 Series Zigbee Thermostat User Guide

expert4house BHT-8000 Heating Thermostat User Guide

Expert4house BAC-1000ALNE Room Thermostat User Guide

EXPERT4HOUSE BAC-9000 Smart Knob Thermostat User Guide