Operation
Selecting the Heat Cycle Rate . . . continued
While it is still in the Setting mode, press the DOWN button to toggle between the various
CYCLE RATES. There are 3 different cycle rates to choose from:
Cr
Cycle Rates
OFF (fixed span)
20 seconds
Cr-0
Cr-1
Cr-2
240 seconds (4 minutes)
Cr 0 is a fixed span (no cycling), with a variance of +/- 0.3°C (+/- 0.6°F). The heating unit
will operate at full power and the power bar will appear full. This function is for users who
do not want their electric heating devices turning on and off frequently. This is the recom-
mended setting for fan-assisted electric heating devices.
Cr 1 (Default) is a 20 second cycle rate with proportional heating. This means the heating
will be turned on and off once every 20 seconds to provide a stable room temperature. This
cycle rate allows a proportional level of power to the heating device. This is indicated on
the thermostat display by the power bar which will be partially filled; indicating the amount
of power going to the heater. This setting is recommended for non-fan assisted baseboards
and electric heating devices and will provide the most energy efficient heating and a stable
temperature.
Cr 2 is a 240 second span. This means the heating will be turned on and off once every
240 seconds. This is the recommended setting for fan assisted heaters, radiant ceilings
and convectors.
9
| General | Details |
|---|---|
| Name | Dimplex DWT431W Non-Programmable Thermostat 4000W Owner’s Manual |
| Make | Dimplex |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.22 MB |

Dimplex X3D Wireless Programmable Thermostat Instruction Manual

DIMPLEX ML2TA 2KW Convector Heater With Thermostat Instruction Manual