Home > Danfoss Heating Solutions > Danfoss Heating Solutions WT-T BasicPlus2 Room Thermostat Installation Guide

Danfoss Heating Solutions WT-T BasicPlus2 Room Thermostat Installation Guide

Installation Guide  
BasicPlus2 WT-T Room Thermostat  
3. Notes  
1. Correct wiring is essential; using instrument to con-  
firm L and N before wiring is recommended.  
2. Don’t remove too much of the insulation cover from  
the wire to avoid short circuit caused by the naked  
wire touching the metal 86 size mounting wall box.  
3. Don’t let the screw press or touch the wire when  
using screws to fix room thermostat in wall box. A  
short-circuit risk exists if the wire insulation cover is  
damaged by the screw, and if the naked wire con-  
nects with the screw.  
4. If walls must be painted, mount the room thermo-  
stat after painting, to avoid dust or paint material  
penetrating the room thermostat and thus damag-  
ing the PCB.  
5. The max. load of relay is 3 A (resistive) or 1 A (induc-  
tive, such as pump or motor). The relay will be dam-  
aged if the load exceeds the limit.  
6. Don’t cover the thermostat, for instance by hanging  
towels directly in front of it.  
7. The room thermostat should be connected to the  
corresponding loop actuator in individual room  
temperature control.  
Danfoss Heating Solutions  
VICUL212  
3
GeneralDetails
NameDanfoss Heating Solutions WT-T BasicPlus2 Room Thermostat Installation Guide
MakeDanfoss Heating Solutions
LanguageEnglish
FiletypePDF (Download)
File size0.09 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Danfoss Heating Solutions WT-T BasicPlus2 Room Thermostat Installation Guide