Advanced settings  
When the thermostat is on, press and hold  
advanced settings.  
and  
(5s) simultaneously to open  
• You can change settings with  
or  
• Press  
to select the settings and proceed.  
• To save the changes and exit advanced settings, press  
1. Sensor type  
7. Lowest setpoint  
0-30 ° C, Standard is 5 ° C  
00: Air sensor / Internal  
01: Floor sensor / External  
02: Max guard / regulator on  
air temperature and limiter  
with floor sensor  
8. Home mode setpoint  
The standard is 22 ° C  
9. Setpoint for away mode  
2. Floor sensor type / External  
0: 10 kOhm  
1: 12 kOhm  
The default is 15 ° C  
10. Brightness in sleep mode  
2: 15 kOhm  
3: 47 kOhm  
1-10, default is 1  
11. Open window detection  
0 = Disabled  
1 = Active  
3. Max Guarding Temperature  
This must be set in the thermostat.  
20-95 ° C, Standard is 27 ° C, '-' No limit.  
12. Restart the system  
Press + or - to change '-' to '==' and wait  
for 5s  
4. Turn  
1-9 ° C, Standard is 2 ° C  
5. Calibration  
13. Reset to factory settings  
Press + or - to change '-' to '==' and wait  
for 5s  
-9 to + 9 ° C, Standard is 0 ° C  
6. Highest set point  
35-90 ° C, Standard is 35 ° C  
Electrical data  
Power: 230 V / 50 Hz  
Circuit breaker: Max 16 A  
Maximum load: 3600 W  
1-pole electronic relay  
Internal power supply with galvanic isloation  
Do not use self-regulating heating cable  
Do not use for contactor control  