• behind a curtain.
• Compatible with the Niko Home Control solar mode
Do not allow air to circulate behind the HVAC thermostat. If needed, fill in any gaps in the flush-mounting box or bus cable duct using PU foam. Push
buttons with display are integrated in a bridge. The thermostat conforms to IEC60730-2-9, EN 50491-5-2, EN 50491-2 and EN 50090-2-3
• Screen type: lit colour display with the dimensions 45 x 45 x 32 (HxWxD)
• Input voltage: 26 Vdc (SELV, safety extra-low voltage)
• Flush-mounting frame
– 1 mm-thick metal
– galvanized on all sides after cutting, even on the cut edges
– with 4 grooves with screw hole of 7 mm
– with 4 screw holes (indicated by a screw symbol) with a diameter of 3 mm for mounting on panels
• Fixing method
– with claws that can be rotated open using screws with a slotted screw head (slot 0.8 x 5 mm), for mounting in a flush-mounting vox with grip
surfaces
– depth of engagement of claws: 31 mm
– claws turn back completely when loosened
• Centre-to-centre distance
– Simple and quick assembly of one or more mechanisms by the indication (chalk line, laser, etc.) of the centre of the flush-mounting frame
– vertical coupling centre-to-centre distance 60 mm by sliding several bases into each other, they lock themselves automatically
– vertical coupling centre-to-centre distance 71 mm using pre-formed lips at the bottom, by folding the lips downwards over a length of 1 mm,
the bases support each other and the centre-to-centre distance is guaranteed.
– horizontal connection of multiple bases is quick and perfect thanks to the folded-up dovetails on the left and right sides
– extra robustness due to the folded-up edges on the outside of the base and the continuation into the inside of the base
• End border: The flush-mounting frame is equipped, both on the top and the bottom, with a dark grey, plastic end border. This border is made
of PC+ASA and is joined to the flush-mounting frame using a melting process. The corners of the two end borders are equipped with rectangu-
lar openings (7.9 x 1.5 mm) each containing a multi-positional snap hook. Thanks to the snap hooks, the 4 rectangular openings ensure that the
faceplate can always be attached flat to the wall, even in cases of untidy plasterwork. This works in two directions: If the flush-mounting box sticks
out of the plasterwork, the multi-positional snap hooks can compensate for a 1 to 1.2 mm margin; if the flush-mounting box is sunk too deeply in
the plasterwork, the snap hooks can compensate for up to a 1.8 mm margin. The end borders also have 4 round openings that ensure the correct
positioning of the faceplate in relation to the central plate.
• Marking: CE
www.niko.eu