Default setting for program schedule
WEEKDAY (MONDAY
Wiring your thermostat
WEEKEND
(SATURDAY)
(6 shows on screen)
WEEKEND
(SUNDAY)
(7 shows on screen)
– FRIDAY)
(1 2 3 4 5 shows on
screen)
Time
display
TIME
TEMPERATURE
TIME
TEMPERATURE
TIME
TEMPERATURE
Period 1
Period 2
Period 3
Period 4
Period 5
Period 6
21℃
21℃
21℃
06:30
08:00
11:30
12:30
18:00
22:30
06:30
08:00
11:30
12:30
18:00
22:30
06:30
08:00
11:30
12:30
18:00
23:00
18℃
18℃
18℃
21℃
21℃
21℃
18
℃
18
℃
18
℃
21℃
21℃
21℃
16℃
16℃
16℃
In the mode of programmable, only the temperature can be
adjusted temporarily, the time could not be adjusted.
H
WG
7. Open window detect function(OWD function)
Please note:
When the Open Window Detect(OWD) mode is enabled in the
parameter setting, the system will automatically stop heating when
it detects a sudden drop of room temperature (2°C in 5 minutes as
default). This is normally caused when a window or door is opened
without turning off the heating device.
Do not over-tighten the terminals in your thermostat as damage may occur.
H for electric heating, External Sensor is optional.
WG for water & gas boiler.
Installing your thermostat
This product is suitable for standard 86mm wall box or European
60mm round box.
In order to save energy,the device will turn off heating and the icon
will show on the screen automatically, it will return to the
previous mode of operation after 30mins, then the icon
disappear. Press any button will exit OWD function during the
heating off period.
1. Keep power off.
Advanced setting
Under the power off status, press
&
simultaneously for 5
seconds for coming into the advance setting mode, the screen will
display all the related No. & dates, then press ︽ or ︾ for dates,
change, then press
parameters will be kept in record after press
to come to the next setting, All of the
2. Connect the wire of power and other equipment into the
terminals.
after finish setting.
Default
parameters
Code
Option
Room
Details
1Adj
Temperature
compensation
-2
-9℃~+9℃
I n:internal sensor(to control
and protect the temperature)
OU:external sensor(to control
and protect the temperature)
AL:internal/external sensor
3. Fix the wall plate into the wall box by a screwdriver
2Sen
Sensor type
In
(internal sensor is for room
temperature controlling, external
sensor is for temperature
protection)
5~60℃, the sensor should
choose AL,when it detect the
temperature is higher than this
limitation,it will close the output
and only the temperature lower
the limitation, the output will
resume.
Temperature
limitation
3Lit
50.0
Switching
Deviation
4. Connect the LCD board into the wallplate.
4dif
5Ltp
6Hit
1
1~5℃
On:start the Anti-freezing
function
Off:closed the Anti-freezing
function
Anti-freezing
function
Off
45
temperature upper
limit setting
35~95℃
Open window
detect function
(OWD)
On:start the OWD function
Off:closed the OWD function
7OEN
8Otl
OFF
15
OWD Detect Time
Range:2~30min
OWD Drop temp.
select (within
detect time)
9Otp
2
Range:2~4℃
OWD Delay time
select (Return to
previous working
status)
WARNING: Please arrange the professional technician
to install this product according to installation drawing
and instruction.
0Pdt
30
-
Range:10~60min
RISK OF ELECTRICAL SHOCK. Disconnect power supply
before making electrical connection. Contact with components
carrying hazardous voltage can cause electrical shock and may
result in severe personal injury or death instruction.
when show“-”and kee press “
for 5 seconds until show“- - -”, it
means return to the restore
factory reset
”
AFAC
Factory Reset