Home > SMART TEMP > SMT-2W5 Smart Temp Wifi Thermostat Instruction Manual
SMT-2W5 Smart Temp Wifi Thermostat Instruction Manual
TM
Smart Temp
Australia
Chassis Ground
Smart Temp SMT-450
Wifi Thermostat
Relay
Receiver
Module
C
Black Wire
Braemar
TH3 Heater
Rh
Red Wire
Sender
Module
SMT-2W5
MAN
Terminals
W1
White Wire
Sender module Typical Colour Codes
Mark Colour Typical Function
1
2
3
Green
Yellow
White
G - Fan
Y1 - 1st Stage Cool
W1 - 1st Stage Heat
or Reversing Valve
Y2 - 2nd Stage Cool
W2 - 2nd Stage Heat or
Aux / Emergency Heat
24 VOLT (HOT)
Use a multimeter to identify which MAN terminals is 24V
and which MAN terminal is 0V.
4
5
Purple
Brown
Red
Black
24R
24C
Use a multimeter (set to AC Volts), place the -ve probe to
chassis and test the voltage on the two MAN terminals.
The one showing 24 AC (approx.) is the “R” terminal, (wired
to Com linked with R on SMT-2W5) the terminal showing
0V is the “W” terminal (wired to 3 on the SMT-2W5)
24 VOLT (COMMON)
Enter the SMT-450 Installer menu (PIN is 0021)
Under “System Type Selection” choose the “Others” option,
then select “Conventional 1H no fan”
ALL CARE AND DILIGENCE HAS BEEN TAKEN IN THE
PREPARATION OF THIS INTERFACE DIAGRAM. SMART TEMP
AUSTRALIA PTY LTD WILL ONLY BE RESPONSIBLE FOR
DAMAGE CAUSED TO THE SMART TEMP PRODUCT, AND ONLY
IF IT HAD BEEN CORRECTLY APPLIED IN ACCORDANCE WITH
THE MANUFACTURES INSTRUCTIONS.
IT IS THE DEALER / CONTRACTORS SOLE RESPONSIBLITY TO
ENSURE CORRECT OPERATION OF THE MAJOR EQUIPMENT IS
MAINTAINED.
TM
Smart Temp
Drawing Revision History
Installation Drawing
Australia
Drawing Name
SMT-450 with SMT-2W5
Braemer Heater TH3
All care has been taken in the preparation of this drawing however
Smart Temp Australia accept no responsibility for damage that may
be caused by using this information. This is a guide only.
By: John K
Unit 20, 1488 Ferntree Gully Road Knoxfield Vic 3180
12-07-2024
REV 1.0
Ph:(03) 9763 0094
Fax (03) 9763 0098
| General | Details |
|---|---|
| Name | SMT-2W5 Smart Temp Wifi Thermostat Instruction Manual |
| Make | SMART TEMP |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.58 MB |

Smart Temp SMT-850 Halo Thermostat User Guide

SMART TEMP SMT-131 Hotel Touchscreen Thermostat User Manual

Smart Temp SMT-450 Flexistat WiFi Thermostat Instructions

SMT-2W5 Smart Temp Wifi Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Smart Temp SMT-450 Wifi Thermostat Sender module typical colour codes Use a multimeter to identify which MAN terminals is 24V and which MAN terminal is 0V. Enter the SMT-450 Installer menu (PIN is 0021). Choose the “Others” option under “System Type Selection.” Select “Conventional 1H no fan.” All care and diligence has been taken in the preparation of this interface diagram. Smart Temp Australia will only be responsible for damage caused to the Smart Temp product if it had been correctly applied in accordance with the manufacturer's instructions. It is the dealer/contractor's sole responsibility to ensure correct operation of the major equipment is maintained. This is a guide only.