Home > SAVANT > SAVANT CLI-W220X-00 Multistat Smart Thermostat User Guide

SAVANT CLI-W220X-00 Multistat Smart Thermostat User Guide

Multistat Smart Thermostat Quick Start Guide  
Box Contents  
Front Panel  
(1) Multistat Smart Thermostat (CLI-W220x-00)  
(1) Installation Kit (075-1419-xx)  
(2) Drywall Anchors (039-0328-xx)  
B
(2) #6 x ¾ inch pan head screws (039-0329-xx)  
(1) GE Wireless Bluetooth Temperature Sensor  
(93129901)  
A
(2) Dolphin splice connectors (028-0581-xx)  
(1) Sheet of Wire Labels (080-0096-xx)  
(1) Product Regulatory Statement (009-1950-xx)  
(1) Quick Start Guide (009-2428-xx, this document)  
Landscape  
Portrait  
Specifications  
LCD Touchscreen - The display is a multi-  
Environmental  
colored touchscreen LCD that includes various  
screens for viewing and configuring the HVAC  
system.  
Temperature 32° to 104° F (0° to 40° C)  
Humidity  
10% to 90% RH (non-condensing)  
A
One touch and swipe operation.  
Dimensions and Weights  
Swipe right for local forecast (when  
enabled).  
Height  
Width  
Depth  
.91 in.  
(7.6 cm) (2.3 cm) (0.14 kg)  
Weight  
.30 lb.  
4.95 in.  
(12.5 cm)  
3.0 in.  
CLI-W220  
Shipping  
Both landscape and portrait type installations  
are supported. During the power-up process,  
the thermostat will auto-detect its positioning  
and make the proper adjustments. Mount the  
backplate, as described below.  
7.0 in.  
(17.8 cm)  
5.0 in.  
(12.7 cm)  
2.0 in. 1.0 lb.  
(5.0 cm) (0.5 kg)  
Power  
Input  
Portrait - Mount the backplate, so the terminal  
strip with the O, G, Y2, Y1, etc. are located  
towards the top. More information is available  
in the Install Thermostat Mounting Plate  
section.  
24V AC (18V AC - 32V AC)  
150 mA RMS typical, 300 mA maximum  
7.2 watts  
B
Current  
Draw  
Max Power  
Landscape - Mount the backplate, so the  
reference designators on the terminal strips  
can be read. If reference designators are upside  
down, rotate the thermostat 180°.  
Cable Requirements  
Power  
HVAC  
#18 AWG  
#18 AWG - thermostat wire (solid)  
Getting Started  
Remote 10k  
Sensor  
#24 AWG - 500 feet (152 meters) max.  
FCC Part 15 Class B  
Savant recommends having the following tools available  
for installation:  
Regulatory  
Pencil  
Safety and  
Emissions  
#2 Phillips screwdriver  
Small slotted screwdriver  
Drill with 5/32 inch drill bit  
Wire stripper  
Contains  
FCC ID:  
VPYLB1ZM  
Contains IC: 772C-LB1ZM  
Needle nose pliers  
Measuring Tape  
RoHS  
Compliant  
Standards  
802.11 b/g/n (2.4 GHz / 5.0 GHz)  
CAUTION! When replacing an older thermostat  
that contains mercury in a sealed tube, do not  
discard it into the trash. Refer to thermostat-  
recycle.org or similar website for information on  
how to dispose of properly.  
Wireless  
IMPORTANT! 802.11r fast roaming is  
not supported.  
Security  
WPA1™, WPA2™, WPA1™ +WPA2™  
Minimum Supported Release  
IMPORTANT! Savant requires the use of at least  
one external sensor. (See Remote Sensors for  
options).  
da Vinci 10.6 and higher  
Savant  
Software  
Multistat Smart Thermostat Quick Start Guide | 009-2428-01  
Copyright ©2025 Savant Systems, Inc 240318  
1
of  
8
45 Perseverance Way, Hyannis MA 02601  
Savant.com | 508.683.2500  
|
GeneralDetails
NameSAVANT CLI-W220X-00 Multistat Smart Thermostat User Guide
MakeSAVANT
LanguageEnglish
FiletypePDF (Download)
File size0.32 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

SAVANT CLI-W220X-00 Multistat Smart Thermostat User Guide
Get the free PDF manual for the SAVANT CLI-W220X-00 Multistat Smart Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

SAVANT CLI-W220X-00 Multistat Smart Thermostat User Guide Overview

Summary of Contents

  • Page 1: Multistat Smart Thermostat Quick Start Guide Box Contents Front Panel Multistat Smart Thermostat (CLI-W220x-00) Installation Kit (075-1419-xx) Drywall Anchors (039-0328-xx) #6 x ¾ inch pan head screws (039-0329-xx) GE Wireless Bluetooth Temperature Sensor (93129901) Dolphin splice connectors (028-0581-xx) Sheet of Wire Labels (080-0096-xx) Product Regulatory Statement (009-1950-xx) Quick Start Guide (009-2428-xx, this document) Specifications LCD touchscreen - The display is a multi-colored touchscreen LCD that includes various screens for viewing and configuring the HVAC system. Temperature 32° to 104° F (0° to 40° C) Humidity 10% to 90% RH (non-condensing) One touch and swipe operation. Dimensions and Weights Both landscape and portrait type installations are supported. During the power-up process, the thermostat will auto-detect its positioning and make the proper adjustments. Power Input 24V AC (18V AC - 32V AC) 150 mA RMS typical, 300 mA maximum Cable Requirements #18 AWG thermostat wire (solid) Getting Started Savant recommends having the following tools available for installation: Pencil, #2 Phillips screwdriver, small slotted screwdriver, drill with 5/32 inch drill bit, wire stripper, needle nose pliers, measuring tape. CAUTION! When replacing an older thermostat that contains mercury in a sealed tube, do not discard it into the trash.
  • Page 2: Remove old thermostat Scroll through and record the current settings and schedules from the old thermostat. Switch OFF power at either the breaker panel or the switch that controls the HVAC system. Open the old thermostat and take a photo of the existing thermostat and wiring. Remove each wire recorded and attach a label that matches the terminal designation from the old thermostat. For new installations or when relocating the thermostat, follow the guidelines below. Locate thermostat on an inside wall away from windows and doors to reduce exposure to drafts or direct sunlight. To adhere to ADA requirements, install thermostat 48 - 54 inches above the floor. The thermostat does not need to be level to operate correctly. Position the mounting plate onto the wall and mark the two mounting holes.
  • Page 3: Making connections requires following specific guidelines for safety and security. Use a small slotted screwdriver to turn the screws in the connector counterclockwise until the silver crimps open enough to slide the wire(s) into the square slots. Strip back insulation on each wire to 1/4 inch and insert the stripped wire into the proper connection. Turn screws clockwise until the crimps tighten around each wire and gently tug on each wire to verify they are secure. The CLI-W220x requires a separate power source to operate, with voltage applied between the RC and 24C terminals. For new installations, connect the wire from the 24V AC HVAC transformer to the RC terminal. When using two transformers, the HVAC system contains three power wires (R, C, and RC). Remove the jumper shunt when the HVAC system contains separate transformers. The RH terminal supplies power to the relays connected to terminals W1, W2, and O. The 24C terminal is the common terminal, required for the thermostat to run.
  • Page 4: HVAC wiring connections depend on the type of HVAC system installed. Power wires may be the only wires required in some installations. Refer to the Making Connections section for safe and secure connections. Additional information on terminal designators and wiring is available in the Multistat Smart Thermostat Deployment Guide. The GE Wireless Bluetooth temperature sensor allows for optimal sensor placement for accurate readings. The sensor must be within Bluetooth range of the thermostat, up to 25 feet in open air. Up to six GE Wireless Bluetooth temperature sensors can be connected to a CLI-W220 at a time. The CLI-W220x includes two thermistor ports for 10K type temperature sensors. 10K sensors do not observe any polarity. Savant offers a range of compatible 10K type sensors for the CLI-W220x.
  • Page 5: Connect to a network How to connect or on-board the thermostat to the local Wi-Fi network from the on-screen menu is described below. Apply power to the thermostat. Verify the Select Network To Connect screen opens. All local networks will be listed. Enter the password for the network using the on-screen keyboards. Select DONE when complete. The thermostat will verify the password credentials and connect to the network. The Configure HVAC System screen opens once the thermostat connects to the network. Edit basic settings for the HVAC system using this device or continue using the HVAC web portal. Select the SKIP button to bypass the onboarding process and go directly to the Configure HVAC System screens. Performing a factory reset wipes the configuration and removes the assigned IP address of the thermostat. After about a 10 second delay, the thermostat will reboot. Select the Mode icon from the Main screen of the thermostat.
  • Page 6: Climate modules expand the capabilities of the thermostat. The modules available include CLI-1WIRE2, CLI-10K4IN, CLI-AUX3, CLI-REL1AUX1, and CLI-PTAC1K1. CLI-1WIRE2 adds up to four 1-wire smart sensors to the system. CLI-10K4IN adds up to four 10K Ω type temperature sensors to the system. CLI-AUX3 adds up to three additional auxiliary relays to the system. CLI-REL1AUX1 adds a set of climate relays and one auxiliary relay to the system. CLI-PTAC1K1 adds relays for use with a PTAC and one 10K Ω temperature sensor. Savant climate modules require 24V AC for power. RS-485 wiring must be connected using a daisy-chained fashion. A 120 Ω terminating resistor may be required on longer wire runs.
  • Page 7: Example 1 shows eight CLI-REL1AUX1 relay modules. Each module uses the HVAC signaling outputs to control a separate zone. Any combination of CLI-REL1AUX1 and CLI-PTAC1K1 modules that equal eight zones is acceptable. Any number of sensor type modules can be added once the eight zones are established. Modules such as the CLI-1WIRE2 and CLI-10K4IN do not affect the maximum. Example 2 shows 3 Aux Relay modules with each relay output controlling a separate damper. Each damper is considered a different zone. Therefore, the maximum number of 8 zones is reached. Any combination of CLI-AUX3 and CLI-REL1AUX1 modules that equal 8 dampers/zones is acceptable. Once the 8 zones are established, any number of sensor modules can be added. Use the diagram for reference only.
  • Page 8: Frequently Asked Questions: The CLI-W220x requires 24V AC that is typically available from a transformer or similar in the HVAC system. The thermostat periodically receives Over The Air (OTA) updates automatically from the Savant Cloud. Most thermostat functions still work when not connected to Wi-Fi, but features requiring a network connection will not. If the thermostat was purchased through a contractor or retailer, contact them to return it. Both Fahrenheit and Celsius are supported. Humidity can be monitored by the included GE Bluetooth Temperature Sensor or an optional remote 1-wire combination temperature smart sensor. The thermostat can function as either a single or dual setpoint thermostat. Scheduling is set up only via the Savant Pro App Climate service. When configured through the web UI, the user can decide which sensors to use and whether to take the average humidity reading. Each thermostat supports a maximum of 8 zones, and the maximum number of climate modules is determined by the number of zones.