Olympia BS-812-P Programmable Thermostat User Manual
INSTALLATION INSTRUCTIONS
INFORMATIONS
GENERAL
European
manufacturers
Removing the plastic separator film between the two batteries, the thermostat is activated. The
current room temperature is shown in the centre of the display. Switch-on the thermostat pressing
the key ΟΝ
PROGRAMMABLE CHRONO - THERMOSTAT
WITH COOLING AND HEATING FUNCTION
Firstly, set the current time and day, by navigating to the menu Hour. Then, set the temperature
pressingthe keys
To enable the night mode press the key
and can be changed navigating to the menuniht. This mode is disabled after8 hours.
To enable the absent mode press the key
for 1 sec. The factory temperature setting is 14.0 OC
.
for 1 sec. The factory temperature setting is 18.0 OC
and can be changed navigating to the menuAbSt.
To enable the boiler (BS-813/P & BS-813/P/C) press the key
command the boiler. The boiler will remain active as long as, it has been defined from the boti
menu. In case, that the value is the factory default, then the boiler can be disabled only pressing
the key
1
2
and the correspoding relay will
Connection diagram for BS-812/P & BS-812/P/C
Remove the pre-
etched entrance
for the connection
cable.
Live wire (L)
NC
C
230V~
To burner (L)
In case, the weekly schedule is enabled and change the temperature manually. The temperature
remainsthe manual selectionfor 5 hours and afterthat the weeklyschedule is been enabled again.
NO
Connection diagram for BS-813/P & BS-813/P/C
BATTERY REPLACEMENT
If the symbol
Remove the front cover and replace the batteries with new one, same type and characteristics (2
alkaline batteries ΑΑ, 1.5V). Replace the front cover. Dispose the old batteries for recycling, in
compliancewith current enviromental protection regulations.
appeared on the display, then the batteriesmust be replaced.
Ÿ Backlight screen
Ÿ 2 AlkalinebatteriesAA(LR06)
Ÿ Boileroutput*
Ÿ Temperature sensor calibration±3.0°C
Live wire (L) to burner
Live wire (L) to Boiler
Ÿ Temperature setting 5.0 – 45.0°C with Ÿ Adjustabledifferential0.2– 1.5°C
Live brown wire (L)
230V
NC
C
NO
C
~
accuracy0.1
Ÿ Temperature measurement 0.0 – 99.9°C
with accuracy0.1
Ÿ Anti-freeze protection to4.5°C
Ÿ Keypad lock.
Ÿ Heating/Cooling function.
Ÿ Temperature Unit(°C, °F)
Ÿ Up to 20 weeklyschedules
Ÿ ECO mode
NO
NC
ANTI-FREEZEPROTECTION
For new installation a third wire for neutral N is not required.
If the room temperature value is 4.5οC, then the thermostat will enable the burner, regardless of
the thermostat status. This mode remainsactive, as long as the temperature is below4.5οC.
4
Ÿ Lock temperature usage limits with PIN
number
THERMOSTAT KEYPAD LOCK
To lockthe thermostat press simultaneously the keys
To unlock press the same keys again.
MENU
ENTER
for 2 sec.
TECHNICAL CHARACTERISTICS
BS-812/P
BS-812/P/C
BS-813/P
BS-813/P/C
2 Alkaline ΑΑ (LR06)
PRODUCT CODE
KEYPAD DESCRIPTION
BATTERIES
FREE RELAY CONTACT
5Α - 250V AC
2 x 5Α - 250V AC
Menu entry
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
CONSTRUCTION MATERIALS
COLOR
IP20
EN 61000-6-1, EN 61000-6-3, EN 60730-1, EN 60730-2-9
Switch-on
Switch-off
Increase value
Remove the battery
separator film.
Cornfirm settings
Night mode
5 to 45 oC
0 - 90% RH
5
6
Menu navigation
Boiler function*/
Menu navigation
Menu navigation
Absent mode
120 x 31 x 80mm
ABS/PC, PC
WHITE or ANTHRACITE (/C)
Descrease value
Menu navigation
Menu exit
click
click
click
180gr
2 years
DIMENSIONAL DRAWING (mm)
1
9
0
g
r
TYPICAL WEIGHT (including batteries)
WARRANTY
Burner indication LED
(Flashing every 4sec)
*
T
h
e
k
e
y
is like this
on BS-813/P & BS-813/P/C
click
DISPLAY INDICATORS DESCRIPTION
7
Day of the week
Burner indication
Boiler indicator
Manual selection
Weekly schedule
MAN.
MOTUWETHFRSASU
80
19
WEEK
Night mode indicator
οCοF
Temperature unit
Absent mode indicator
Current Temperature
Messages
Thermostat enabled
Thermostat disabled
ON
120
31
105
OFF
Low battery indicator
WARRANTY
Thank you for your trust in our products
Olympia Electronics - European manufacturer
1.5m
Time
The selection temperature is smaller than the current temperature
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is
specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies
each product. This warranty ceases to exist if the buyer does not follow the technical instructions included in
official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs
or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products
that have been damaged can be returned to the premises of our company for repair or replacement, as long as
the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the
buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the
buyer the transportation cost.
The selection temperature and the differential is greater than the current temperature
The selection temperature is between the selection temperature and the selection + the defferential
Ÿ
Ÿ
Wallmounting with recommended height: 1.5mfrom the floor on an internalwall.
Do not mount the devices in recesses, shelves, behind curtains or doors, or above or near heat
sources.
Avoid directexposure to sunlight
Ÿ
The device is considered an electronic device for disposal in accordance with the European
Guidelinesand may not be disposed of as domesticgarbage.
WARNING HEALTH AND SAFETY INFORMATION
National safety regulations
Failure to comply with national safety regulations may result in personal injury, discomfort,
property damage and other potential hazards.
!
Ÿ
Ÿ
Ÿ
Dispose of the devicethrough channels providedfor this purpose.
Comply with alllocal and currentlyapplicablelaws and regulations.
Dispose of emptybatteriesin designated collectionpoints.
!
Ÿ
Ÿ
Comply with any national regulations and comply with appropriate safety regulations
You shall comply with any additional national regulatory informations.
Risk of electric shock
Disconnect the power supply before any interference with the system
*BS-813/P & BS-813/P/C model with boiler output
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
WARNING! installation, configuration, start-up and maintenance must be done by qualified
personnel only.
4
5
940813002_09_002
940813002_09_002
| General | Details |
|---|---|
| Name | Olympia BS-812-P Programmable Thermostat User Manual |
| Make | OLYMPIA |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.97 MB |