Home > OLYMPIA > Olympia BS-812-P Programmable Thermostat User Manual

Olympia BS-812-P Programmable Thermostat User Manual

INSTALLATION INSTRUCTIONS  
INFORMATIONS  
GENERAL  
European  
manufacturers  
Removing the plastic separator film between the two batteries, the thermostat is activated. The  
current room temperature is shown in the centre of the display. Switch-on the thermostat pressing  
the key ΟΝ  
PROGRAMMABLE CHRONO - THERMOSTAT  
WITH COOLING AND HEATING FUNCTION  
Firstly, set the current time and day, by navigating to the menu Hour. Then, set the temperature  
pressingthe keys  
To enable the night mode press the key  
and can be changed navigating to the menuniht. This mode is disabled after8 hours.  
To enable the absent mode press the key  
for 1 sec. The factory temperature setting is 14.0 OC  
.
for 1 sec. The factory temperature setting is 18.0 OC  
and can be changed navigating to the menuAbSt.  
To enable the boiler (BS-813/P & BS-813/P/C) press the key  
command the boiler. The boiler will remain active as long as, it has been defined from the boti  
menu. In case, that the value is the factory default, then the boiler can be disabled only pressing  
the key  
1
2
and the correspoding relay will  
Connection diagram for BS-812/P & BS-812/P/C  
Remove the pre-  
etched entrance  
for the connection  
cable.  
Live wire (L)  
NC  
C
230V~  
To burner (L)  
In case, the weekly schedule is enabled and change the temperature manually. The temperature  
remainsthe manual selectionfor 5 hours and afterthat the weeklyschedule is been enabled again.  
NO  
Connection diagram for BS-813/P & BS-813/P/C  
BATTERY REPLACEMENT  
If the symbol  
Remove the front cover and replace the batteries with new one, same type and characteristics (2  
alkaline batteries ΑΑ, 1.5V). Replace the front cover. Dispose the old batteries for recycling, in  
compliancewith current enviromental protection regulations.  
appeared on the display, then the batteriesmust be replaced.  
Ÿ Backlight screen  
Ÿ 2 AlkalinebatteriesAA(LR06)  
Ÿ Boileroutput*  
Ÿ Temperature sensor calibration±3.0°C  
Live wire (L) to burner  
Live wire (L) to Boiler  
Ÿ Temperature setting 5.0 – 45.0°C with Ÿ Adjustabledifferential0.21.5°C  
Live brown wire (L)  
230V  
NC  
C
NO  
C
~
accuracy0.1  
Ÿ Temperature measurement 0.0 – 99.9°C  
with accuracy0.1  
Ÿ Anti-freeze protection to4.5°C  
Ÿ Keypad lock.  
Ÿ Heating/Cooling function.  
Ÿ Temperature Unit(°C, °F)  
Ÿ Up to 20 weeklyschedules  
Ÿ ECO mode  
NO  
NC  
ANTI-FREEZEPROTECTION  
For new installation a third wire for neutral N is not required.  
If the room temperature value is 4.5οC, then the thermostat will enable the burner, regardless of  
the thermostat status. This mode remainsactive, as long as the temperature is below4.5οC.  
4
Ÿ Lock temperature usage limits with PIN  
number  
THERMOSTAT KEYPAD LOCK  
To lockthe thermostat press simultaneously the keys  
To unlock press the same keys again.  
MENU  
ENTER  
for 2 sec.  
TECHNICAL CHARACTERISTICS  
BS-812/P  
BS-812/P/C  
BS-813/P  
BS-813/P/C  
2 Alkaline ΑΑ (LR06)  
PRODUCT CODE  
KEYPAD DESCRIPTION  
BATTERIES  
FREE RELAY CONTACT  
5Α - 250V AC  
2 x 5Α - 250V AC  
Menu entry  
DEGREES OF COVER PROTECTION  
PRODUCED IN ACCORDANCE WITH  
OPERATION TEMPERATURE RANGE  
RELATIVE HUMIDITY  
EXTERNAL DIMENSIONS  
CONSTRUCTION MATERIALS  
COLOR  
IP20  
EN 61000-6-1, EN 61000-6-3, EN 60730-1, EN 60730-2-9  
Switch-on  
Switch-off  
Increase value  
Remove the battery  
separator film.  
Cornfirm settings  
Night mode  
5 to 45 oC  
0 - 90% RH  
5
6
Menu navigation  
Boiler function*/  
Menu navigation  
Menu navigation  
Absent mode  
120 x 31 x 80mm  
ABS/PC, PC  
WHITE or ANTHRACITE (/C)  
Descrease value  
Menu navigation  
Menu exit  
click  
click  
click  
180gr  
2 years  
DIMENSIONAL DRAWING (mm)  
1
9
0
g
r
TYPICAL WEIGHT (including batteries)  
WARRANTY  
Burner indication LED  
(Flashing every 4sec)  
*
T
h
e
k
e
y
is like this  
on BS-813/P & BS-813/P/C  
click  
DISPLAY INDICATORS DESCRIPTION  
7
Day of the week  
Burner indication  
Boiler indicator  
Manual selection  
Weekly schedule  
MAN.  
MOTUWETHFRSASU  
80  
19  
WEEK  
Night mode indicator  
οCοF  
Temperature unit  
Absent mode indicator  
Current Temperature  
Messages  
Thermostat enabled  
Thermostat disabled  
ON  
120  
31  
105  
OFF  
Low battery indicator  
WARRANTY  
Thank you for your trust in our products  
Olympia Electronics - European manufacturer  
1.5m  
Time  
The selection temperature is smaller than the current temperature  
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty is  
specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which accompanies  
each product. This warranty ceases to exist if the buyer does not follow the technical instructions included in  
official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs  
or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products  
that have been damaged can be returned to the premises of our company for repair or replacement, as long as  
the warranty period is valid.  
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the  
buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the  
buyer the transportation cost.  
The selection temperature and the differential is greater than the current temperature  
The selection temperature is between the selection temperature and the selection + the defferential  
Ÿ
Ÿ
Wallmounting with recommended height: 1.5mfrom the floor on an internalwall.  
Do not mount the devices in recesses, shelves, behind curtains or doors, or above or near heat  
sources.  
Avoid directexposure to sunlight  
Ÿ
The device is considered an electronic device for disposal in accordance with the European  
Guidelinesand may not be disposed of as domesticgarbage.  
WARNING HEALTH AND SAFETY INFORMATION  
National safety regulations  
Failure to comply with national safety regulations may result in personal injury, discomfort,  
property damage and other potential hazards.  
!
Ÿ
Ÿ
Ÿ
Dispose of the devicethrough channels providedfor this purpose.  
Comply with alllocal and currentlyapplicablelaws and regulations.  
Dispose of emptybatteriesin designated collectionpoints.  
!
Ÿ
Ÿ
Comply with any national regulations and comply with appropriate safety regulations  
You shall comply with any additional national regulatory informations.  
Risk of electric shock  
Disconnect the power supply before any interference with the system  
*BS-813/P & BS-813/P/C model with boiler output  
72nd km. O.N.R. Thessaloniki-Katerini  
P.C. 60300 P.O. Box 06 Εginio Pierias Greece  
WARNING! installation, configuration, start-up and maintenance must be done by qualified  
personnel only.  
4
5
940813002_09_002  
940813002_09_002  
GeneralDetails
NameOlympia BS-812-P Programmable Thermostat User Manual
MakeOLYMPIA
LanguageEnglish
FiletypePDF (Download)
File size0.97 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Olympia BS-812-P Programmable Thermostat User Manual