Nexans N-Comfort Kt+ Thermostat Instruction Manual
Led indication lights show the status:
Name of thermostat
•
•
•
•
•
•
red ON → comfort temp reached
red breathing → heating ON
green ON → eco temp reached
green breathing → heating ON
both leds blinking → error
at power up red led is ON for 4 seconds to indicate floor heating or snow melting mode and in air
mode green led is ON for 4 seconds
A free and descriptive name shown in N-Comfort App.
Heating mode
Thermostat can measure and adjust floor temperature, air temperature or it can melt snow and ice from
stairs and driveways in snow melting mode. Note! During eco-hours in snow melting mode the output is
turned OFF.
Floor temperature min and max
Min and max values specify active range of knob.
Additionally with N-Comfort App (see next chapter):
•
•
red blinking → bluetooth connection
green blinking → confirm to save changes by shortly turning the knob to OFF state
Floor temperature offset (calibration)
If user's temperature measurement has offset to knob setpoint this setting is used to calibrate it. Note, floor
sensor inside the floor construction is much warmer than real temperatures measured in room.
ADVANCED USE
You can access all the thermostat data with a free of charge N-Comfort App running on Android and iOS
mobile devices. With the App you read logged temperatures, modify settings and define a weekly user
program. App can also generate email reports. Follow the guides in N-Comfort App. Thermostat indicates
the mobile device connection with fast blinking red led.
Air temperature min and max
In air mode it specifies active knob range.
Air temperature offset (calibration)
If user's temperature measurement has offset to dial setpoint this setting is used to calibrate it. Note, Air
temperature mode uses external sensor cable.
1
Settings
Thermostat has several settings which can easily be adjusted with N-Comfort App.
Note! Remember to save changes before leaving the setting page.
Snow melting ON temperature min and max
Min and max setting specify the active knob range. When outdoor temperature is below this setting point
the snow melting operation is active.
8
9
| General | Details |
|---|---|
| Name | Nexans N-Comfort Kt+ Thermostat Instruction Manual |
| Make | Nexans |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.22 MB |