Home > Nexans > Nexans N-Comfort Kt+ Thermostat Instruction Manual

Nexans N-Comfort Kt+ Thermostat Instruction Manual

Led indication lights show the status:  
Name of thermostat  
red ON comfort temp reached  
red breathing heating ON  
green ON eco temp reached  
green breathing heating ON  
both leds blinking error  
at power up red led is ON for 4 seconds to indicate floor heating or snow melting mode and in air  
mode green led is ON for 4 seconds  
A free and descriptive name shown in N-Comfort App.  
Heating mode  
Thermostat can measure and adjust floor temperature, air temperature or it can melt snow and ice from  
stairs and driveways in snow melting mode. Note! During eco-hours in snow melting mode the output is  
turned OFF.  
Floor temperature min and max  
Min and max values specify active range of knob.  
Additionally with N-Comfort App (see next chapter):  
red blinking bluetooth connection  
green blinking confirm to save changes by shortly turning the knob to OFF state  
Floor temperature offset (calibration)  
If user's temperature measurement has offset to knob setpoint this setting is used to calibrate it. Note, floor  
sensor inside the floor construction is much warmer than real temperatures measured in room.  
ADVANCED USE  
You can access all the thermostat data with a free of charge N-Comfort App running on Android and iOS  
mobile devices. With the App you read logged temperatures, modify settings and define a weekly user  
program. App can also generate email reports. Follow the guides in N-Comfort App. Thermostat indicates  
the mobile device connection with fast blinking red led.  
Air temperature min and max  
In air mode it specifies active knob range.  
Air temperature offset (calibration)  
If user's temperature measurement has offset to dial setpoint this setting is used to calibrate it. Note, Air  
temperature mode uses external sensor cable.  
1
Settings  
Thermostat has several settings which can easily be adjusted with N-Comfort App.  
Note! Remember to save changes before leaving the setting page.  
Snow melting ON temperature min and max  
Min and max setting specify the active knob range. When outdoor temperature is below this setting point  
the snow melting operation is active.  
8
9
GeneralDetails
NameNexans N-Comfort Kt+ Thermostat Instruction Manual
MakeNexans
LanguageEnglish
FiletypePDF (Download)
File size0.22 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Nexans N-Comfort Kt+ Thermostat Instruction Manual