Chrono-thermostat wall-mounting (Fig. 4):  
install the mount (2) fixing it to the wall with expansion  
plugs (1) and the supplied screws (3).  
N.B: the selection described above is temporary and will  
be lost when the batteries of the Chrono-thermostat are  
removed. In this case, the default setting value (‘IMG BUS’  
generator) is restored.  
N.B.: this mode is not activated if the generator is con-  
trolled by the Gateway only via the operation request con-  
tact (in this case, if communication with the Chrono-ther-  
mostat fails, the Gateway removes the operation request  
and any system antifreeze protections are fully controlled  
by the generator).  
1.10  
Type of system configuration without Wi-  
Fi connection.  
e Smartech Plus system is paired to the type of generator  
connected by completing the user registration procedure  
on the “Smartech” app (paragraph 1.9). If there is no Wi-  
Fi connection available when first starting the system  
(and therefore the above-mentioned procedure cannot  
be performed), the type of generator connected can be  
selected temporarily as follows:  
N.B.: pay attention to correctly position the spirit level  
(5) downwards.  
2. SAFETY MODE  
SMARTECH PLUS  
Release the body of the Chrono-thermostat (4) from the ta-  
ble base by pulling it, then insert the 2 LR03 (AAA) batteries  
supplied in the specific compartment (Fig. 5), then press-  
couple the Chrono-thermostat on the mount (2). To replace  
the batteries, release the Chrono-thermostat (4) from the  
wall mount (2) by pulling it and repeat the above operations.  
N.B.: in this mode, room antifreeze protection is no  
longer available; only that of the generator remains active.  
e Smartech Plus system activates the ‘Safety mode’ if  
Bluetooth communication fails between Gateway and  
Chrono-thermostat.  
Basically this could occur if the two devices are further  
away than the maximum allowed distance for the specific  
installation (in this case the message ‘ Disconnected’  
appears on the Chrono-thermostat display), or if the  
Chrono-thermostat batteries are dead.  
In ‘Safety mode’ the Gateway keeps the last status received  
from the Chrono-thermostat for 30 minutes, aſter which  
the generator only guarantees production of domestic  
hot water with a setpoint of 50°C. If communication with  
the Chrono-thermostat is reset, the system resumes its  
normal functioning.  
- make the electrical connections on the Gateway as  
described in Paragraph 1.5, then power the device;  
3. TECHNICAL CHARACTERISTICS  
CHRONO-THERMOSTAT:  
- insert the batteries in the Chrono-thermostat;  
• Dimensions:... diameter 71,5 mm, thickness 35,5 mm  
• Wireless technology: ....................... Bluetooth 4.1 BLE  
• ermostat / Gateway  
communication distance:......................Max. 10mt (**)  
• Reading range:....................................from 0°C to 40°C  
• Reading accuracy:............................................+/- 0.1°C  
• Setting range:...................................from 4.5°C to 30°C  
Temperature increase range:................................. 0.5°C  
• Power Supply: ........2 LR03 (AAA) 1.5V batteries (not  
rechargeable) battery life about 1 and a half years (*).  
At the end of the installation, remove the protective film  
from the display of the chrono-thermostat.  
- once the Immergas logo is displayed, keep the  
Chrono-thermostat pressed until a dot is shown and  
then press again until the list of the type of generators  
appears;  
1
2
3
- rotate the Chrono-thermostat to the desired type of  
generator;  
- press the Chrono-thermostat to confirm.  
4
5
4. WIRING DIAGRAMS  
GATEWAY CONNECTION WIRING DIAGRAM  
4
Key:  
N.B.: IMG BUS is a communication protocol only used by  
certain Immergas appliances,  
(see the instruction booklet of the appliance);  
A30 - Smartech Plus Gateway  
G4 - Gateway DC power supply unit  
X3 - Modbus RS485  
X4 - Potential-free contact Max. 0.5 A - 230 Vac  
(generator operation request)  
L/N - 230 Vac / 50 Hz power supply  
X1 - +5 Vdc power supply  
X2 - IMG BUS  
N.B.: ModBus RS485 is a communication protocol only  
used by certain Immergas appliances,  
(see the instruction booklet of the appliance);  
N.B.: the X2 (IMG BUS) and X3 (ModBus RS485) connec-  
tors must be connected to SELV devices.  
N.B.: the cables to be used for X2 and X3 connections must  
have an adequate cross-section and minimum isolation  
of 300V;  
BR - Brown  
BL - Blue  
W - White  
Y - Yellow  
N.B.: use the two wire sleeves supplied with the power  
supply unit, inserting them on the White (W) and Yellow  
(Y) wires on the side of the terminal block (X4), to further  
isolate them from the Gateway inside;  
A30  
5
N.B.: For connection via ModBus RS485, apply the 120  
Ohm resistance supplied on the relative terminals of the  
appliance in parallel with the Modbus connection, (see the  
instruction booklet of the appliance).  
1.8 Gateway - Chrono-thermostat coupling.  
Aſter having powered the generator, the Gateway and  
the Chrono-thermostat, wait 30 seconds before perfor-  
ming any setting on the system so that communication  
between the Gateway, generator and Chrono-thermostat  
is properly established.  
N.B.: all "Smartech Plus" chrono-thermostats are already  
configured to work correctly with your Gateway, so they  
do not need any additional configuration to make them  
work.  
6
CONNECTION TO BOILER VIA COMMUNICATION BUS (IMG BUS)  
In case of a malfunction, the Gateway and ermostat  
can be re-coupled by proceeding as follows:  
- make sure you have turned on the Gateway for at least  
5 minutes;  
Key:  
A30 - Smartech Plus Gateway  
G4 - Gateway DC power supply unit  
1 - Boiler  
- Keep the "Reset" button on the Gateway pressed until  
the indication on the "BLE" LED switches from 5 quick  
blinks a second to one blink a second;  
2 - Cable not supplied by Immergas  
BR - Brown  
BL - Blue  
W - White  
Y - Yellow  
- with Chrono-thermostat set on the main window, press  
and hold the same key for 3 seconds until the "Mode"  
or "Program" menu appears, then rotate the Chrono-  
thermostat to display the “Settings” menu. At this point  
again press and hold the key to select the "Diagnostic"  
menu and press to confirm and to enter the menu;  
1
N.B.: connect the X2 terminals to the IMG BUS boiler  
terminals normally provided for CAR X2 communication,  
indicated as 44 (or 40) and 41. (See the instruction booklet  
of the appliance);  
- press the Chrono-thermostat again, the message "Pai-  
ring" will appear on the display. When "Disconnected"  
appears, the Chrono-thermostat is paired to the Gate-  
way;  
A30  
N.B.: the Gateway can be powered by being connected to  
terminals A (L line) and B (N Neutral) (230 Vac / 50 Hz  
auxiliary boiler power supply) if available,  
- press and hold the Chrono-thermostat to go back to  
the main menu;  
(see the instruction booklet of the appliance).  
- switch off (removing power) and switch the Gateway  
back on.  
2
1.9 Application download and installation on mobile  
devices (smartphone).  
7
Using the mobile device on which to install the appli-  
cation, connect to the App store of reference: App Store  
(Apple) or Play Store (Android) and type in “Immergas  
Smartech” in the search field. e app works with IOS 12  
operating system or higher (Apple) and Android 10 or  
higher. Select the free “Smartech” application and wait for  
its download and installation on the mobile device used.  
Open the “Smartech” App and download the instruction  
manual by pressing “Download Instructions and war-  
nings. Follow its instructions to register and pair it with  
the installed Smartech Plus system.  
CONNECTION TO BOILER VIA ROOM THERMOSTAT CONTACT (On/Off), from models without communication bus  
Key:  
A30 - Smartech Plus Gateway  
G4 - Gateway DC power supply unit  
1 - Boiler  
BR - Brown  
BL - Blue  
W - White  
Y - Yellow  
e manual can be downloaded from the website www.  
immergas.com.  
N.B: the encryption method of the Wi-Fi network must be  
WPA2 PSK; otherwise malfunctions could occur.  
1
N.B.: connect the terminals X4 of the Gateway to the boiler  
terminals provided for connection of the Room ermostat,  
indicated as 40 and 41,  
(see the instruction booklet of the appliance);  
A30  
N.B.: the Gateway can be powered by being connected to  
terminals A (L line) and B (N Neutral) (230 Vac / 50 Hz  
auxiliary boiler power supply) if available,  
(see the instruction booklet of the appliance).  
8
2
GeneralDetails
NameIMMERGAS 3.030909 Smartech Plus Smart Chrono Thermostat Installation Guide
MakeIMMERGAS
LanguageEnglish
FiletypePDF (Download)
File size0.58 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

IMMERGAS 3.030909 Smartech Plus Smart Chrono Thermostat Installation Guide