Home > Generic > Generic HY610 WiFi Digital Heating Thermostat User Manual

Generic HY610 WiFi Digital Heating Thermostat User Manual

WIFI Digital Heating Thermostat User Manual  
Activate window function  
Room temp  
Setting temp  
Many thanks for your selection of our products and services, and also for your trust and  
support to us.  
Cooling mode, the icon blinking means cooling mode output  
Search for "Smart life" from google play or  
App store to Download the Wifi App  
Turn on the thermostat, press and hold the  
key combination “ ” and “ ” to activate  
WIFI distribution network icon  
Operation key  
symbols represent  
Turn ON/OFF: short press to turn on/ turn off; Power on, long press to power off  
1. Short press to switch automatic mode and manual mode(It works when the  
thermostat is networked)  
2. Turn on thermostat, long press for 3-5 seconds to enter into programmable setting  
Product Specifications  
☆ Power: 90-240Vac 50/60Hz  
☆ Range of temperature display::1~70°C  
☆ Insulating condition: Normal environment  
☆ Running program: Set per 1 week as a cycle  
☆ Output: Switch relay  
3. Turn off thermostat, long press for 3-5 seconds to enter into advance option A  
☆ Display accuracy::0.5°C  
1. Decrease key  
☆ Probe sensor::NTC(10k)1%  
☆ Contact capacity::3A/(WW);16A/(WE)  
☆ Limit temperature range::1~70°C  
☆ Range of temperature adjustment::5~35°C  
2. Long press to lock /unlock  
1. Increase key  
2. Long press to inquire external sensor temperature ( only available for BN item select N3 in  
the advance option B)  
☆ Installation: recessed type (in the wall)  
☆ Size(mm):86*86  
3. In the program model, press  
or  
enter to temporary manual mode  
Wiring Diagram  
Advanced option  
Displays  
Power off state, long press  
for 3-5 seconds to access advanced option A.  
to choose the option, and adjust data by  
From A1 to AE, short press or  
switch next option.Remain about 5 seconds after finish setting will quit setting.  
, short press  
Factory Default  
room -1  
to  
NO  
Setting Options  
Data Setting Function  
as the corrected  
±9℃  
Measure Temperature  
Calibration  
1
(Displayed  
temperature )  
05:0.5℃  
10:1℃  
25: 2.5℃  
Start/stop working  
temperature difference  
setting  
2
3
10  
High temperature  
protection temperature  
difference setting  
1-9°C  
2°C  
Description of icon  
Programming mode  
Manual mode  
Temporary manual mode  
N1:Internal sensor (high temperature  
protection close)  
N2:External sensor (high temperature  
protection close)  
Holiday mode, days and temperature can be set to run in countdown mode(APP setting)  
Heating, icon disappears to stop heating  
External NTC sensor  
Child lock  
Options of sensor  
control  
WIFI connection, flashing EZ distribution mode  
N1  
4
N3:Internal sensor control  
temperature ,external sensor limit temperature  
(external sensor detect the temperature is  
higher than highest temperature of external  
Wifi status: Disconnection  
Cloud icon: flashing AP distribution network mode  