Eberle UTE 3500 Smart Home Capable Flush Mounted Thermostat Installation Guide

Overview of preset values of each use case  
Adjustable at Installer Menu (level 2)  
Function description  
P2  
P3  
P4  
P5  
P6  
P7  
P8  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
Floor probe type (resistance in kΩ; UTE 3800-U only)  
Min. floor limit in °C (UTE 3800-U only)  
Max. floor limit in °C (UTE 3800-U only)  
Control method  
00 (not fitted)  
00 (not fitted)  
33  
33  
33  
10  
10  
10  
40  
40  
40  
PWM 20 Min  
PWM 10 Min  
2 point control 0,5 K  
2 point control 0,5 K  
PWM 20 Min  
PWM 20 Min  
2 point control 0,5 K  
2 point control: On/Off time in min  
02  
02  
02  
Application type (Control sensor)  
Room sensor  
Room sensor  
Room sensor  
Room sensor  
Room sensor with floor limit  
Floor probe  
Room sensor with floor limit  
Actuator type (UTE 3500 only)  
Normally close valve  
Normally close valve  
Normally close valve  
Normally close valve  
Universal input configuration  
Setback input  
Setback input  
Setback input  
Setback input  
Setback input  
Setback input  
Setback input  
Heating/Cooling input configuration (UTE 3500 only)  
Occupancy – Switch to unoccupied delay in min  
Occupancy – Switch to occupied delay in sec  
Valve protection  
On  
10  
60  
On  
14  
03  
On  
10  
60  
On  
14  
03  
On  
10  
60  
Off  
On  
10  
60  
Off  
10  
60  
On  
14  
03  
Off  
Off  
02  
20  
02  
10  
60  
Off  
10  
60  
Off  
Valve protection – Max. idle time in days  
Valve protection – Min. exercise time in min  
Temporal limit acc. to EN 50559 (UTE 3800-U only)  
Window open detection  
Off  
Off  
02  
20  
02  
Off  
Off  
02  
20  
02  
On  
Off  
02  
20  
02  
On  
Off  
02  
20  
02  
Off  
02  
20  
02  
Off  
02  
20  
02  
Window open detection – Threshold in 0.1°C steps  
Window open detection – Event duration in min  
Window open detection – Guard period in min  
Installer Menu (Level 2):  
12. Matter WiFi Configuration  
For advanced settings of individual menu items after confirming the Installer menu (level 1) preset:  
How-to Video::  
Enter code: 32  
Menu  
item  
Function description  
Option and display of  
dot-matrix.display  
UTE 3500  
UTE 3800-U  
01  
Floor probe type (resistance in kΩ; UTE 3800-U only)  
00: No floor probe fitted  
02:  
2
10: 10  
12: 12  
15: 15  
33: 33  
Via Matter the thermostat can be connected to smart home apps and the respective controllers/hubs from Apple, Google, Amazon and Samsung.  
To integrate the thermostat into a Smart Home App and the respective Matter WiFi network, scan the QR code on the back of the logic module with  
a smartphone or type in the eleven-digit Matter provisioning code.  
02  
03  
04  
Min. floor limit in °C (UTE 3800-U only)  
Max. floor limit in °C (UTE 3800-U only)  
Control method  
10 … 39  
11 … 40  
Press the [O] button for 5 seconds until the thermostat displaysJn“ for Join Mode. The WiFi LED lights up yellow.  
01: PWM 20 Min  
02: PWM 10 Min  
03: PWM 5 Min  
04: 2 point control 0.5 K  
05: 2 point control 0.1 K  
05  
06  
2 point control: On/Off time in min  
Application type (control sensor)  
01 … 10  
If an error occurs during connection, the controller displaysEr“ for Error: The WiFi LED lights up red.  
00: Room sensor (internal)  
01: Floor probe (external)  
02: Room sensor with floor limit  
07  
08  
Actuator type  
nC: normally closed valves  
no: normally open valves  
Universal input configuration  
01: Setback input – use  
unoccupied setpoint,  
when energized  
Acknowledge with [O] and restart the Matter WiFi configuration.  
02: Presence sensor:  
use occupied setpoint,  
when energized  
13. User Menu  
09  
Heating/Cooling input configuration (UTE 3500 only)  
no: Disable H/C-signal  
YES: Enable (H/C-signal,  
switch to cooling mode,  
when energized)  
To access the user menu, press and hold the [-] and [O] buttons simultaneously for 3 seconds. The WiFi LED lights up yellow.  
Browse through the menuitems by pressing the [+] or [-] buttons.  
Confirm your selection by pressing the [O] button.  
10  
11  
12  
Occupancy – Switch to unoccupied delay in min  
Occupancy – Switch to occupied delay in sec  
Valve protection  
00 … 60 min  
To exit the menu without saving: Press the [-] and [O] buttons or wait for 10 sec.  
00 … 60 sec  
The following settings can be adjusted:  
no: Disable  
YES: Enable  
User Menu  
item  
Function description  
Idle brightness  
Option and display  
of the dot matrix LEDs  
Default values  
UTE 3500  
UTE 3800-U  
01  
02  
00: (= off, recommended)  
01: 10%  
02: 25%  
03: 50%  
04: 75%  
00  
13  
14  
15  
Valve protection – Max. idle time in days  
Valve protection – Min. exercise in min  
01 … 14 days  
To save energy and to improve LED  
longevity 00 is recommended.  
01 …10  
Temporal limit acc. to EN50559 (UTE 3800-U w/ floor  
control only)  
no: Disable  
YES: Enable (5 Min off Time)  
05: 100%  
Activity timeout  
10: 10 sec  
30: 30 sec  
60: 60 sec  
2m: 2 min  
4m: 4 min  
60  
16  
Window open detection  
no: Disable  
YES: Enable  
17  
18  
19  
Window open detection – Threshold in 0.1°C steps  
Window open detection – Event duration in min  
Window open detection – Guard period in min  
01 … 50  
10 … 90  
03  
04  
05  
06  
07  
08  
09  
10  
11  
98  
Show icons in idle mode  
no: Disable  
YES: Enable  
YES  
YES  
0
00 … 90  
(00 = No Guard time)  
Setpoint change indication  
(via Smart Home)  
no: Disable  
YES: Enable  
Room sensor correction  
in 0,1°C steps  
–2,5 … +2,5  
in 0,1°C steps  
11. Error indication  
Min. setpoint  
5 … 30 °C (room control range)  
10 … 40 °C (floor control range)  
room: 5 /  
floor: 10  
In the event of sensor errors, the controller detects which sensor is faulty:  
E1 = room sensor error  
E2 = floor probe error  
Max. setpoint  
5 … 30 °C (room control range)  
10 … 40 °C (floor control range)  
room: 30 /  
floor: 40  
Unoccupied temperature (Heating)  
in °C  
min. setpoint … max. setpoint  
min. setpoint … max. setpoint  
18  
22  
no  
no  
no  
Unoccupied temperature (Cooling)  
in °C  
Heating off (Frost protection active)  
no: Cancel and return  
Yes: Confirm  
Stand-by (Heating off, display & WiFi  
off, frost protection active)  
no: Cancel and return  
Yes: Confirm  
Reset Matter fabric  
no: Cancel and return  
Yes and hold [O] for 3 seconds:  
confirm  
This product should not be disposed of with household  
waste. Please recycle the products where facilities for  
electronic waste exist. Check with your local authorities  
for recycling advice.  
99  
Reset user data  
no: Cancel and return  
Yes and hold [O] for 3 seconds:  
confirm  
no  
GeneralDetails
NameEberle UTE 3500 Smart Home Capable Flush Mounted Thermostat Installation Guide
MakeEBERLE
LanguageEnglish
FiletypePDF (Download)
File size0.21 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EBERLE UTE 1002-55, UTE 1002-50 Flush Mounted Room Thermostat Instructions
EBERLE UTE 1002-55, UTE 1002-50 Flush Mounted Room Thermostat Instructions
EBERLE UTE 1032-55, UTE 1032-50 Flush Mounted Room Thermostat Owner’s Manual
EBERLE UTE 1032-55, UTE 1032-50 Flush Mounted Room Thermostat Owner’s Manual
EBERLE UTE Series Flush Mounted Room Thermostat Owner’s Manual
EBERLE UTE Series Flush Mounted Room Thermostat Owner’s Manual

Eberle UTE 3500 Smart Home Capable Flush Mounted Thermostat Installation Guide