ADEPT T6100 Thermostat Instruction Manual

1. Room temp calibraon: Calibrate the temp detected by room sensor.  
2. Floor temp calibraon: Calibrate the temp detected by floor sensor.  
3. An-frozen funcon: This op�on allow you to bring warmth to your plant and pet with a lower temp.  
displays when you turn off the thermostat.  
No. Name  
Default  
Ranges  
1
Room temp calibraon 0.0°C  
-5.0°C -- 5.0°C  
2
3
Floor temp calibraon  
0.0°C  
-5.0°C -- 5.0°C  
OF(OFF)  
An-frozen funcon  
ON  
In hydronic hea�ng system, it will keep away from freezing.  
4. Sensor selecon:  
00 Room sensor: Run by room sensor.  
01 Floor sensor: Run by floor sensor.  
ON  
4
5
An-frozen temp  
5.0°C  
5.0°C -- 15.0°C  
00: Room sensor  
01: Floor sensor  
02: Both sensors  
20.0°C -- 50.0°C  
00: °C  
Sensor selecon  
01: Floor sensor  
02 Both sensors: Run by room sensor with floor temp limit.  
5. Floor temp limit: If you choose both sensors, floor temp limit must be set to protect floor.  
6. Temp unit: °C and °F can be selected.  
6
7
Floor temp limit  
Temp unit  
30.0°C  
00: °C  
01: °F  
7. Output delay: This op�on help you avoid inadvertent opera�on on hea�ng.  
8. Temp deviaon: The devia�on is 1°C. The thermostat start to work when the actual temp is 1°C lower than set  
temp and stop to work when the actual temp is 1°C higher than set temp.  
9.Reverse output: This func�on works for the cooling system. When the temp is 1°C higher than set temp, the  
thermostat will disconnect the cooling system. otherwise, it will connect the cooling system.  
10. Schedule: Select a weekly schedule for the Edit. There are 2 op�ons:  
7: each day from Mon to Sun can be set individually.  
8
Output delay  
00: 00s  
00: 00s  
01: 30s  
02: 60s  
03: 90s  
9
Temp deviaon  
01: 1.0°C  
00: 0.5°C  
01: 1.0°C  
02: 2.0°C  
03: 3.0°C  
00: OFF  
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.  
11. Adapve funcon: Aer several days of installa�on and use, Adap�ve func�on ensures that the required temp  
has already been reached when the next event begins.  
10  
11  
12  
13  
Reverse output  
Schedule  
00: OFF  
01: 5+1+1  
01: ON  
01: ON  
00: 7  
12. Reset: All parameters are restored to default values.  
01: 5+1+1  
00: OFF  
7.9 Open window detec�on  
This func�on only works when room sensor or both sensors is selected. The thermostat with this  
func�on will shut off automa�cally for 15 min when the window opens, as it can detect that the  
room temp plummets.  
Adapve funcon  
Reset  
01: ON  
00: No  
00: No  
01: YES  
11  
12  