SEALEY FH2010.V2 2000W Fan Heater with Thermostat User Manual
NOTE: Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or
installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and
clean the appliance or perform user maintenance.
Children of less than 3 years should be kept away unless continuously supervised.
2. i INTRODUCTION
Tough composite case with integral carry handle. Can be seated in a vertical or horizontal position. 2-Position heat settings control two 1000W
heating elements. Full range ambient room thermostat maintains temperature at preset level. Fan doubles as cool air blower for use in the
summer. Supplied with 3-pin plug.
3. i SPECIFICATION
1000W FAN ONLY
LAMP LIGHTS
2000W
Model..................................................................... FH2010.V2
Voltage: ............................................................................ 230V
Power: .................................................................. 1000/2000W
Dimensions:...............................................230 x 240 x 120mm
WHEN HEATER
OPERATING
MIN
4. OPERATION
4.1.
Position heater where required, either horizontally or vertically
on a level surface ensuring that the air intake and outlet are
not obstructed in any way.
MAX
4.2.
4.3.
Plug the heater into the mains supply.
THERMOSTATIC
TEMPERATURE CONTROL
Set the thermostat knob to the half way position as shown in
fig.1.
fig.1
4.4.
4.5.
4.6.
4.7.
The fan heater will switch on when the selector switch is set to
one of the two power settings (1000W or 2000W).
Once the room reaches the set temperature the heater will switch on and off automatically to maintain that temperature. Adjust the
position of the thermostat knob to obtain a comfortable room temperature.
If the fan fails to operate when a power setting is selected the thermostatic temperature control may be set too low. Turn the knob slowly
towards max until the fan starts.
For a cooling effect turn the selector switch to the fan only setting.
5. MAINTENANCE
5.1.
5.2.
WARNING! Before attempting any maintenance ensure the unit is unplugged from the mains power supply and that it is cool.
Clean the heater with a soft dry cloth. DO NOT use abrasives or solvents.
Periodically check the heater grille to ensure it is not blocked.
NOTE: This heater is fitted with a safety device which will cut the power should the heater overheat. If this happens you should
disconnect the heater from the mains supply for a minimum of 3 minutes allowing the heater to cool, ensure the heater is not covered or
anything is obstructing the vents. Plug the heater back into the electrical socket and switch the heater back on.
No other maintenance is necessary. If you experience a problem with your heater or if the power lead or plug is damaged contact your
local authorised service agent for repair. DO NOT dismantle or tamper with the heater as this may be dangerous and will invalidate your
warranty.
5.3.
Parts support is available for this product. Please email sales@sealey.co.uk or telephone 01284 757500
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic
Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way.
REGISTER YOUR
Contact your local solid waste authority for recycling information.
PURCHASE HERE
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
Original Language Version
FH2010.V2 Issue:6 (1) 07/11/23
| General | Details |
|---|---|
| Name | SEALEY FH2010.V2 2000W Fan Heater with Thermostat User Manual |
| Make | SEALEY |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.18 MB |