Home > GENERAL LIFE > GENERAL LIFE MITRA HT10 RF Digital Room Thermostat User Guide

GENERAL LIFE MITRA HT10 RF Digital Room Thermostat User Guide

RECEIVER  
BATTERY PLACEMENT  
ENGLISH  
1-Manual Operation Button:  
By disabling the Receiver, it enables you  
to use your boiler manually.  
2-Pairing Button:  
1
2
3
DIGITAL ROOM THERMOSTAT  
generallife.com.tr  
Allows to pair the Receiver with the  
Room Thermostat.  
SERIES:  
MITRA, ARUNA, CERES, GAIA, ILLONA, NORA, SENNA, THERMA  
3-Receiver LED Light  
4-Receiver Power Cable Input  
5-Boiler Connection Cable Input  
Remove the battery cover located on the back of your Room  
Thermostat. Insert 2 new AAA alkaline batteries into the battery  
housing with the correct battery direction and close the battery cover.  
Replacebothbatteriesatthesametime.  
HT10 RF/HT10S RF/HT11S RF USER MANUAL  
DIGITAL ROOM THERMOSTAT  
GENERAL SPECIFICATIONS  
4
5
WARNING!  
HT10 RF/HT10S RF/HT11S RF is a wireless room thermostat. The  
user can adjust the room temperature with the required temperature  
and get morecomfortable and economic heating.  
When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would  
be out of warranty.  
RECEIVER LED DESCRIPTIONS  
PreciseTemperatureMeasurement  
WirelessConnection  
Steady Red  
Receiver has power but Receiver and  
Pleasethrow yourdead batteriesinto the wastebin for batteries.  
ON/OFFControl  
SERIES:  
MITRA, ARUNA, CERES, GAIA,  
ILLONA, NORA, SENNA, THERMA  
Room Thermostat are not paired.  
Blinking Green  
Steady Green  
Waiting for pairing signal from Room Thermostat.  
RECEIVER PLACEMENT  
HT10 RF/HT10S RF/HT11S RF AND EQUIPMENTS  
Room Thermostat  
Holder  
Alkaline  
Battery  
Receiver and Room Thermostat are paired.  
Boiler is not operating.  
The important things to note for the Receiver  
placement is avoiding physical contact between  
the Receiver and boiler, and protecting it against  
materialssuch asliquid,dust etc.  
3 Short Orange  
Blinking  
Operate the boiler signal has reached to the  
Receiver.  
HT10 RF/HT10S RF/HT11S RF  
USER MANUALS  
Steady Orange  
Boiler is operating.  
3 Short Green  
Blinking  
Shut the boiler down signal has reached to the  
Receiver.  
The devices should be placed in order to minimize the damage to the  
received and transmitted signals by paying attention to the following  
points;  
Dowels and Screws  
Receiver  
Blinking Orange  
Boiler is operating in manual mode.  
Blinking Red  
Receiver did not get a signal from the  
Room Thermostat for 22 minutes or longer and  
boiler has shut down.  
The devicesshould not be mounted on metalsurfaces.  
The devices should not be installed close to electrical cables and  
electronic equipment such ascomputers and televisionunits.  
The devices should not be installed near large metal structures or  
other building materials using fine metal meshes such as special  
glass or special concrete.  
TECHNICAL DATA  
Room Thermostat  
ROOM THERMOSTAT PLACEMENT  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room  
or side of window should be avoided. Also anywhere close to heating  
units such as radiator, stove and spots which get direct sun lights  
would not be suitable. Room Thermostat needs to be located above  
Dimensions ( H / L / W )  
Operating Current  
85.7mm / 85.7mm / 33.5mm  
3V DC (2 x AAA alkaline battery)  
0.1oC  
Distance between the Room Thermostat and the Receiver should  
not exceed 20metersor 2 floors.  
Temperature Measurement  
Accuracy  
Receivermust be installed atleast50cmawayfrom the boiler.  
Operating Sensivity  
Operating Temperature Range  
Battery Life  
0.3oC  
RECEIVER SETUP  
First, shut down your boiler and your boiler's power source with all  
electricalcurrent (fuse,socketetc.)  
(5oC) – (30oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
the floor  
150 cm height. Few trials may be made to find the most  
Operating Temperature  
Storage Temperature  
convenientspot.  
As shown in the connection diagram, connect one end of the boiler  
connection cable to the COM and the other to the NO input.of the  
Receiver.  
Receiver  
Connect the other ends of the cable -which you connected to the  
Receiver- to room thermostat connection terminal as shown in your  
boiler's user manual.  
min.20 cm  
Dimensions  
90mm / 90mm / 25mm  
230V AC  
Operation Current  
Relay NO Switching Current  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
(-20oC) – (+60oC)  
You must first connect the Receiver power cable to the Receiver  
and then to thefuse to which theboiler is connected.  
After completing the cable connection process,firstly turn on your  
fuse and then yourboiler.  
Storage Temperature  
ROOM THERMOSTAT  
By pressing the Receiver's manual usage button for 2 seconds, you  
should see the Orange Light blinking on the Receiver. In this way,  
after making sure that the boiler is operating, press the same button  
again for 2 seconds and seethatthe Orange LEDturns off.  
Set up the Room Thermostat to pair the Receiver with the Room  
Thermostat.  
Indicator LED  
Adjustment Knob  
RoomThermostatIndicator LED Descriptions  
If it blinks once  
Room Thermostat sends a close signal to the  
Receiver and the heating unit stops operating.  
Room Thermostat sends an open signal to  
the Receiver and the heating unit starts.  
generallife.com.tr  
If it blinks twice  
If it blinks three times Room Thermostat sends a pairing signal to  
the Receiver.  
1
2
3
GeneralDetails
NameGENERAL LIFE MITRA HT10 RF Digital Room Thermostat User Guide
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.04 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE MITRA HT10 RF Digital Room Thermostat User Guide
Get the free PDF manual for the GENERAL LIFE MITRA HT10 RF Digital Room Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE MITRA HT10 RF Digital Room Thermostat User Guide Overview

Summary of Contents

  • Page 1: Receiver battery placement is essential for proper operation. The manual operation button allows for manual use of the boiler. The pairing button is used to connect the receiver with the room thermostat. Receiver LED light indicators provide information on power and connection status. The receiver should be placed away from the boiler and protected from liquids and dust. Room thermostat placement should avoid areas with direct sunlight or near heating units. The distance between the room thermostat and the receiver should not exceed 20 meters. Receiver setup requires shutting down the boiler and connecting cables correctly. The room thermostat should be set up to pair with the receiver for proper functionality. Indicator LED descriptions provide feedback on the status of the heating unit.
  • Page 2: WARRANTY CERTIFICATE In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair at full expense by the manufacturer. If your boiler has on-off connections, your Room Thermostat is compatible. We recommend that the connection between your Receiver and your boiler should be made by professionally qualified persons. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty. The Room Thermostat measures the temperature of its environment every 5 seconds. The warranty period starts from the invoice date and is against manufacturing defects for 2 years. Devices and apparatus are delivered to the customer in working condition. The customer can make complaints and appeals to consumer courts or consumer arbitration committees. The warranty document must be kept by the customer during the warranty period. In case of malfunctioning, it is tested whether the malfunction is caused by a customer or manufacturer fault.