RECEIVER
BATTERY PLACEMENT
ENGLISH
1-Manual Operation Button:
By disabling the Receiver, it enables you
to use your boiler manually.
2-Pairing Button:
1
2
3
DIGITAL ROOM THERMOSTAT
generallife.com.tr
Allows to pair the Receiver with the
Room Thermostat.
SERIES:
MITRA, ARUNA, CERES, GAIA, ILLONA, NORA, SENNA, THERMA
3-Receiver LED Light
4-Receiver Power Cable Input
5-Boiler Connection Cable Input
Remove the battery cover located on the back of your Room
Thermostat. Insert 2 new AAA alkaline batteries into the battery
housing with the correct battery direction and close the battery cover.
Replacebothbatteriesatthesametime.
HT10 RF/HT10S RF/HT11S RF USER MANUAL
DIGITAL ROOM THERMOSTAT
GENERAL SPECIFICATIONS
4
5
WARNING!
HT10 RF/HT10S RF/HT11S RF is a wireless room thermostat. The
user can adjust the room temperature with the required temperature
and get morecomfortable and economic heating.
When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would
be out of warranty.
RECEIVER LED DESCRIPTIONS
PreciseTemperatureMeasurement
WirelessConnection
Steady Red
Receiver has power but Receiver and
Pleasethrow yourdead batteriesinto the wastebin for batteries.
ON/OFFControl
SERIES:
MITRA, ARUNA, CERES, GAIA,
ILLONA, NORA, SENNA, THERMA
Room Thermostat are not paired.
Blinking Green
Steady Green
Waiting for pairing signal from Room Thermostat.
RECEIVER PLACEMENT
HT10 RF/HT10S RF/HT11S RF AND EQUIPMENTS
Room Thermostat
Holder
Alkaline
Battery
Receiver and Room Thermostat are paired.
Boiler is not operating.
The important things to note for the Receiver
placement is avoiding physical contact between
the Receiver and boiler, and protecting it against
materialssuch asliquid,dust etc.
3 Short Orange
Blinking
Operate the boiler signal has reached to the
Receiver.
HT10 RF/HT10S RF/HT11S RF
USER MANUALS
Steady Orange
Boiler is operating.
3 Short Green
Blinking
Shut the boiler down signal has reached to the
Receiver.
The devices should be placed in order to minimize the damage to the
received and transmitted signals by paying attention to the following
points;
Dowels and Screws
Receiver
Blinking Orange
Boiler is operating in manual mode.
Blinking Red
Receiver did not get a signal from the
Room Thermostat for 22 minutes or longer and
boiler has shut down.
The devicesshould not be mounted on metalsurfaces.
The devices should not be installed close to electrical cables and
electronic equipment such ascomputers and televisionunits.
The devices should not be installed near large metal structures or
other building materials using fine metal meshes such as special
glass or special concrete.
TECHNICAL DATA
Room Thermostat
ROOM THERMOSTAT PLACEMENT
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room
or side of window should be avoided. Also anywhere close to heating
units such as radiator, stove and spots which get direct sun lights
would not be suitable. Room Thermostat needs to be located above
Dimensions ( H / L / W )
Operating Current
85.7mm / 85.7mm / 33.5mm
3V DC (2 x AAA alkaline battery)
0.1oC
Distance between the Room Thermostat and the Receiver should
not exceed 20metersor 2 floors.
Temperature Measurement
Accuracy
Receivermust be installed atleast50cmawayfrom the boiler.
Operating Sensivity
Operating Temperature Range
Battery Life
0.3oC
RECEIVER SETUP
First, shut down your boiler and your boiler's power source with all
electricalcurrent (fuse,socketetc.)
(5oC) – (30oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
the floor
150 cm height. Few trials may be made to find the most
Operating Temperature
Storage Temperature
convenientspot.
As shown in the connection diagram, connect one end of the boiler
connection cable to the COM and the other to the NO input.of the
Receiver.
Receiver
Connect the other ends of the cable -which you connected to the
Receiver- to room thermostat connection terminal as shown in your
boiler's user manual.
min.20 cm
Dimensions
90mm / 90mm / 25mm
230V AC
Operation Current
Relay NO Switching Current
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
(-20oC) – (+60oC)
You must first connect the Receiver power cable to the Receiver
and then to thefuse to which theboiler is connected.
After completing the cable connection process,firstly turn on your
fuse and then yourboiler.
Storage Temperature
ROOM THERMOSTAT
By pressing the Receiver's manual usage button for 2 seconds, you
should see the Orange Light blinking on the Receiver. In this way,
after making sure that the boiler is operating, press the same button
again for 2 seconds and seethatthe Orange LEDturns off.
Set up the Room Thermostat to pair the Receiver with the Room
Thermostat.
Indicator LED
Adjustment Knob
RoomThermostatIndicator LED Descriptions
If it blinks once
Room Thermostat sends a close signal to the
Receiver and the heating unit stops operating.
Room Thermostat sends an open signal to
the Receiver and the heating unit starts.
generallife.com.tr
If it blinks twice
If it blinks three times Room Thermostat sends a pairing signal to
the Receiver.
1
2
3
| General | Details |
|---|---|
| Name | GENERAL LIFE MITRA HT10 RF Digital Room Thermostat User Guide |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.04 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE MITRA HT10 RF Digital Room Thermostat User Guide Overview
Summary of Contents
- Page 1: Receiver battery placement is essential for proper operation. The manual operation button allows for manual use of the boiler. The pairing button is used to connect the receiver with the room thermostat. Receiver LED light indicators provide information on power and connection status. The receiver should be placed away from the boiler and protected from liquids and dust. Room thermostat placement should avoid areas with direct sunlight or near heating units. The distance between the room thermostat and the receiver should not exceed 20 meters. Receiver setup requires shutting down the boiler and connecting cables correctly. The room thermostat should be set up to pair with the receiver for proper functionality. Indicator LED descriptions provide feedback on the status of the heating unit.
- Page 2: WARRANTY CERTIFICATE In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair at full expense by the manufacturer. If your boiler has on-off connections, your Room Thermostat is compatible. We recommend that the connection between your Receiver and your boiler should be made by professionally qualified persons. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty. The Room Thermostat measures the temperature of its environment every 5 seconds. The warranty period starts from the invoice date and is against manufacturing defects for 2 years. Devices and apparatus are delivered to the customer in working condition. The customer can make complaints and appeals to consumer courts or consumer arbitration committees. The warranty document must be kept by the customer during the warranty period. In case of malfunctioning, it is tested whether the malfunction is caused by a customer or manufacturer fault.