AJAX108846 White Smart Wifi Thermostat Instruction Manual
1. Room temp calibra�on: Calibrate the temp detected by room sensor.
2. Floor temp calibra�on: Calibrate the temp detected by floor sensor.
3&4. An�-frozen func�on: This op�on allow you to bring warmth to your plant and pet with a lower temp.
displays when you turn off the thermostat.
No. Name
Default
Ranges
1
Room temp calibra�on 0.0°C
-5.0°C -- 5.0°C
2
3
Floor temp calibra�on
0.0°C
-5.0°C -- 5.0°C
OF(OFF)
An�-frozen func�on
ON
In hydronic hea�ng system, it will keep away from freezing.
5. Sensor selec�on:
00 Room sensor: Run by room sensor.
01 Floor sensor: Run by floor sensor.
ON
4
5
An�-frozen temp
5.0°C
5.0°C -- 15.0°C
00: Room sensor
01: Floor sensor
02: Both sensors
20.0°C -- 50.0°C
00: °C
Sensor selec�on
01: Floor sensor
02 Both sensors: Run by room sensor with floor temp limit.
6. Floor temp limit: If you choose both sensors, floor temp limit must be set to protect floor.
7. Temp unit: °C and °F can be selected.
6
7
Floor temp limit
Temp unit
30.0°C
00: °C
01: °F
8. Output delay: This op�on help you avoid inadvertent opera�on on hea�ng.
9. Temp devia�on: The devia�on is 1°C. The thermostat start to work when the actual temp is 1°C lower than set
temp and stop to work when the actual temp is 1°C higher than set temp.
10.Reverse output: This func�on works for the cooling system. When the temp is 1°C higher than set temp, the
thermostat will disconnect the cooling system. otherwise, it will connect the cooling system.
11. Schedule: Select a weekly schedule for the Edit. There are 2 op�ons:
7: each day from Mon to Sun can be set individually.
8
Output delay
00: 00s
00: 00s
01: 30s
02: 60s
03: 90s
9
Temp devia�on
01: 1.0°C
00: 0.5°C
01: 1.0°C
02: 2.0°C
03: 3.0°C
00: OFF
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.
12. Adap�ve func�on: A�er several days of installa�on and use, Adap�ve func�on ensures that the required temp
has already been reached when the next event begins.
10
11
12
13
Reverse output
Schedule
00: OFF
01: 5+1+1
00: OFF
00: No
01: ON
00: 7
13. Reset: All parameters are restored to default values.
01: 5+1+1
00: OFF
7.9 Open window detec�on
This func�on only works when room sensor or both sensors is selected. The thermostat with this
func�on will shut off automa�cally for 15 min when the window opens, as it can detect that the
room temp plummets.
Adap�ve func�on
Reset
01: ON
00: No
01: YES
11