Home > ajax > AJAX108846 White Smart Wifi Thermostat Instruction Manual

AJAX108846 White Smart Wifi Thermostat Instruction Manual

1. Room temp calibraon: Calibrate the temp detected by room sensor.  
2. Floor temp calibraon: Calibrate the temp detected by floor sensor.  
3&4. An-frozen funcon: This op�on allow you to bring warmth to your plant and pet with a lower temp.  
displays when you turn off the thermostat.  
No. Name  
Default  
Ranges  
1
Room temp calibraon 0.0°C  
-5.0°C -- 5.0°C  
2
3
Floor temp calibraon  
0.0°C  
-5.0°C -- 5.0°C  
OF(OFF)  
An-frozen funcon  
ON  
In hydronic hea�ng system, it will keep away from freezing.  
5. Sensor selecon:  
00 Room sensor: Run by room sensor.  
01 Floor sensor: Run by floor sensor.  
ON  
4
5
An-frozen temp  
5.0°C  
5.0°C -- 15.0°C  
00: Room sensor  
01: Floor sensor  
02: Both sensors  
20.0°C -- 50.0°C  
00: °C  
Sensor selecon  
01: Floor sensor  
02 Both sensors: Run by room sensor with floor temp limit.  
6. Floor temp limit: If you choose both sensors, floor temp limit must be set to protect floor.  
7. Temp unit: °C and °F can be selected.  
6
7
Floor temp limit  
Temp unit  
30.0°C  
00: °C  
01: °F  
8. Output delay: This op�on help you avoid inadvertent opera�on on hea�ng.  
9. Temp deviaon: The devia�on is 1°C. The thermostat start to work when the actual temp is 1°C lower than set  
temp and stop to work when the actual temp is 1°C higher than set temp.  
10.Reverse output: This func�on works for the cooling system. When the temp is 1°C higher than set temp, the  
thermostat will disconnect the cooling system. otherwise, it will connect the cooling system.  
11. Schedule: Select a weekly schedule for the Edit. There are 2 op�ons:  
7: each day from Mon to Sun can be set individually.  
8
Output delay  
00: 00s  
00: 00s  
01: 30s  
02: 60s  
03: 90s  
9
Temp deviaon  
01: 1.0°C  
00: 0.5°C  
01: 1.0°C  
02: 2.0°C  
03: 3.0°C  
00: OFF  
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.  
12. Adapve funcon: Aer several days of installa�on and use, Adap�ve func�on ensures that the required temp  
has already been reached when the next event begins.  
10  
11  
12  
13  
Reverse output  
Schedule  
00: OFF  
01: 5+1+1  
00: OFF  
00: No  
01: ON  
00: 7  
13. Reset: All parameters are restored to default values.  
01: 5+1+1  
00: OFF  
7.9 Open window detec�on  
This func�on only works when room sensor or both sensors is selected. The thermostat with this  
func�on will shut off automa�cally for 15 min when the window opens, as it can detect that the  
room temp plummets.  
Adapve funcon  
Reset  
01: ON  
00: No  
01: YES  
11  
12  
GeneralDetails
NameAJAX108846 White Smart Wifi Thermostat Instruction Manual
Makeajax
LanguageEnglish
FiletypePDF (Download)
File size0.37 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
AJAX108845 White Digital Programmable Thermostat User Guide
AJAX108845 White Digital Programmable Thermostat User Guide
AJAX ETHT82 White Touch Screen Thermostat Instruction Manual
AJAX ETHT82 White Touch Screen Thermostat Instruction Manual

AJAX108846 White Smart Wifi Thermostat Instruction Manual