Remote (Wired) Room Thermostat
Caspian EC linking kit (EC only)
This accessory measures room temperature and switches off the
heater when the set temperature is reached. This thermostat is hard
wired and connects directly into either the heater’s terminal block or
power supply.
The linking kit allows for the creation of master and slave units (up to
four units), by allowing a 0-10 V signal to be transmitted through its
cabling. This allows one fan speed controller, or room thermostat to
control multiple units. It can also be used to control multiple units by
means of a BMS. Where master and slave units are required this must
be clearly identified at time of ordering.
Remote (Wired) Room Thermostat Tamper Proof
This accessory measures room temperature and switches off the
heater when the set temperature is reached. This thermostat is hard
wired and connects directly into either the heater’s terminal block
or power supply. The thermostat has a secure cover that deters
unwanted adjustment of the room temperature set point.
External control harness (EC only)
This accessory is generally used to permit a remote manual speed
adjustment on an EC variant Caspian. It is possible to provide speed
control to a master unit and to then utilise the EC linking kit to link to
any slave units.
Wall mounted control switch
Allows the product to be controlled from a switch mounted on
the wall rather than the product. Linking to the heater is made by
replacing the existing switch connections with the connections on the
control switch.
Proportional Heat Output Controller
This accessory controls the fan speed and hence the heat output of
the unit. These controls are available in integral (low level units) and
in a remote format (high level units). PHOC’s are available in two
standard temperature settings, either 15 - 25oC, or 11 - 21oC.
When the room temperature is at or below the lowest set point
(11oC or 15oC) the fan speed will run at its maximum speed to give
fastest heat up time. As the room temperature increases towards the
upper set point (21oC or 25oC), the fan speed modulates downwards
towards a minimum level. Customised temperature ranges can be
produced upon request
Flexible hoses
Flexible connections are a convenient way of connecting a heater into
your system. They will provide an easy to achieve connection from
your first-fix pipe work. In addition they will provide for a level of
expansion and contraction in rigid pipe work and mitigating possible
sound and vibration transmission.
Thermostat T1
Adjustable low temperature cut-out (LTC)
This is a factory fitted air thermostat suited to EC products installed
at low level. This control provides a tamperproof room temperature
control and is ideal for use in public buildings.
This cut out device allows the user to set the water temperature
(between 30oC and 90oC) at which the product will start to emit
heat. It is more accurate than the standard fitted LTC (set at 35oC)
and enables more flexible use with both low system temperature heat
pumps and higher system temperature boilers including biomass that
can produce 80oC flow temperatures.
Thermostat T2
A T2 thermostat is used to control the fan speed on low level products
only. The objective in using this control is to facilitate a faster heat
up period in a room. An installer or commissioning engineer can
determine the temperature set point at which the fan speed is
changed from high to low utilising our speed change circuit board. A
typical set point would be 16oC, where temperatures below this level
would trigger a higher fan speed.
Plinth
The optional plinth creates an attractive floor standing unit and also
conceals the pipe work from view. This can also be invaluable where
it is necessary to prevent contact with heating pipes by vulnerable
groups. A plinth can also add an additional level of protection from
the ingress of dust on hard flooring surfaces. Available in 100mm and
150mm high versions and in black or white.
Thermostat and Auto-Speed control (T1/T2)
This accessory serves two purposes. Firstly, it becomes an integral
room thermostat for the unit providing localised control and secondly,
the heat output will be changed according to the temperature in the
room. For example, the fan may work on full power up to 18oC and
above this temperature move to a lower fan speed. Normally the fan
speeds used will be medium and low. The components used are as per
the thermostat T1 and thermostat T2 detailed above.
As part our commitment to continuous improvement Smith’s Environmental Products may change the specifications of its products without prior
notification or public announcement. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and
shall not form part of any contract. All dimensions are in mm unless otherwise stated. Please visit our website for the most up to date information.
Issue 003 | January 2025
+44 (0) 1245 324 900 | sales@smithsep.co.uk | SmithsEP.co.uk
| General | Details |
|---|---|
| Name | Smith s HAGA95001 Remote Wired Room Thermostat Owner’s Manual |
| Make | Smith s |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.05 MB |

Smith s HAGA95001 Remote Wired Room Thermostat Owner’s Manual Overview
Summary of Contents
- Page 1: Accessories - Glossary Remote (Wired) Room Thermostat measures room temperature and switches off the heater when the set temperature is reached. This thermostat is hard wired and connects directly into either the heater’s terminal block or power supply. Caspian EC linking kit allows for the creation of master and slave units by transmitting a 0-10 V signal through its cabling. Remote (Wired) Room Thermostat Tamper Proof has a secure cover that deters unwanted adjustment of the room temperature set point. External control harness permits a remote manual speed adjustment on an EC variant Caspian. Wall mounted control switch allows the product to be controlled from a switch mounted on the wall. Proportional Heat Output Controller controls the fan speed and heat output of the unit, available in integral and remote formats. Flexible hoses provide an easy connection from first-fix pipe work and mitigate sound and vibration transmission. Adjustable low temperature cut-out (LTC) allows the user to set the water temperature at which the product will start to emit heat. A T2 thermostat controls the fan speed on low level products to facilitate a faster heat up period in a room. The optional plinth creates an attractive floor standing unit and conceals the pipe work from view.
- Page 2: Accessories - Matrix Caspian products include various models such as SL/FF/UV/TT, EXT, UVC, Skyline, and Skyline E. Caspian adjustable low temperature cut-out options are available. Caspian thermostat (T1) and EC auto-speed control (T2) with circuit board are offered. Caspian proportional heat output controllers are available in different temperature ranges and configurations. Caspian remote switching on/off relay (24V AC coil) is included. Factory fitted controls are standard across products. Bespoke RAL paint finishes can be requested. Antibacterial and antimicrobial paint finishes are available. Specifications may change without prior notification. All dimensions are in mm unless otherwise stated.