Home > GENERAL LIFE > GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
ScreenIndicators
As shown in the picture above, press the screwdriver forward from the
space shown, bend the tabs and separate the front cover. Insert 2 new
AAA alkaline batteries in the battery housing with the correct battery
direction. Replace both batteries at the same time. Then align the
front part of your Room Thermostat to the back and squeeze it
towards theback.
ENGLISH
5
DIGITAL ROOM THERMOSTAT
6
7
1
2
generallife.com.tr
Low Battery Warning: When the “
” icon appears on the screen, it
means “low battery warning”. It is recommended to replace the
batterieswhen thiswarning appears.
Warning: When the product is not used for a long period (more than 15
days), remove the batteries. Otherwise, malfunctions that may occur
would beout of warranty.
3
4
SENNA 270 USER MANUAL
GENERALSPECIFICATIONS
DIGITAL ROOM THERMOSTAT
1
2
3
4
5
Room Temperature
SENNA 270 is a wired room thermostat. The user can adjust the room
temperature with the required temperature and get more comfortable
and economic heating/cooling.
DifferentModeOptions(Comfort Modeand Economy Mode)
PreciseTemperatureMeasurement
HeatingCalibration
Pleasethrowyourdead batteriesinto thewastebin for batteries.
Set Temperature
Economy Mode
ROOMTHERMOSTATWIRINGDIAGRAM
Comfort Mode
Battery Indicator
HEATING/COOLING UNIT
ON/OFFControl
WiredConnection
TPIAlgorithm
Heating Indicator
- If the Heating Indicator is blinking, the heating unit is
SENNA 270
USER MANUAL
6
working.
Heating/Cooling Modes
- If the Heating Indicator is steady, the heating unit is not
working.
Cooling Indicator
SENNA270ANDEQUIPMENTS
SENNA 270
Alkaline
Battery
Dowels and
Screws
- If the Cooling Indicator is blinking, the cooling unit is
Room Thermostat
7
working.
NO COM
- If the Cooling Indicator is steady, the cooling unit is not
working.
ROOMTHERMOSTATPLACEMENT
Warning!
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room
or side of window should be avoided. Also anywhere close to
heating/cooling units such as radiator, stove and spots which get
direct sun lights would not be suitable. Room Thermostat needs to be
located above the floor 150 cm height. Few trials may be made to find
themostconvenientspot.
Operations within the heating
installationmustbecarriedout byprofessionally qualified persons.
/
cooling unit or the electrical
TECHNICALDATA
Dimensions
Operating Current
Relay NO Switching Current
ROOMTHERMOSTATTEMPERATURECALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You may need to calibrate your Room Thermostat if you
would like to get the same temperature values with other
thermometersin yourliving space.
While your device is turned off, press and hold the "On/Off"button
for 3seconds.
85mm / 125mm / 19mm
3V DC (2 x AAA alkaline battery)
2A/30VDC (Resistive load)
0.5A/125VAC (Resistive load)
0.1oC
Temperature Measurement
Accuracy
Operating Temperature Range
Battery Life
(5oC) – (30oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
Press the "On/Off" button until the “
” menu appers. In order to
Operating Temperature
Storage Temperature
see the desired temperature, set the temperature difference by
press the “Temperature Adjustment Buttons”. This value can be
arrangedbetween“-8oC" and “+8oC".
ROOMTHERMOSTAT
ButtonsFunctions
To save the settings and exit, press the "On/Off" button until the
deviceturnsoff.
Note:Recommended tempreturecalibrationis“0.0oC”.
1
FACTORY SETTINGS RESET
2
3
You can reset your Room Thermostat to its default factory settings.
This operation resets the mode temperature values, calibration
setting and heating/coling modes to factory setting. To reset your
Room Thermostattofactorysetting:
4
5
6
While your device is turned off, press and hold the "On/Off"button
for 3seconds.
BATTERY PLACEMENT
Before starting, power off the device connected to the Room
Thermostatand makesurethattheenergy iscutoff.
Pressthe“On/Off” button until “
”menu appears.
” option by using “+” or “-”
1
2
3
4
5
6
ON/OFF and Setting Button
While in the “
” menu, select the “
Economy Mode
buttons and pressthe“On/Off” button.
Comfort Mode
Your devicewillbeturned off and resettofactorysettings.
Heating/Cooling Modes (Press and hold for 5 seconds.)
Temperature Adjustment (Increasing)
Temperature Adjustment (Decreasing)
MODESETTINGS
There are 2 modes in the Room Thermostat. These are Comfort Mode
“
” and Economy Mode “ ”. Modes work according to the pre-set
temperaturevaluesadjustedbyuser.
Inordertochange thecomfort mode temperaturevalue;
Pressand hold thecomfort mode button for 3seconds.
Change thetemperaturevaluebypressing “+” or“-“ buttons.
Press the comfort mode button once to save the changes you have
madeorwait10seconds.
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL LIFE 270 Wireless Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.88 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE HT25 RF Wireless Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Low battery warning: When the icon appears on the screen, it means low battery warning. It is recommended to replace the batteries when this warning appears. Warning: When the product is not used for a long period (more than 15 days), remove the batteries. SENNA 270 is a wired room thermostat. The user can adjust the room temperature for more comfortable and economic heating/cooling. Room thermostat needs to be placed in the room which is used most frequently, avoiding areas with direct sunlight or near heating/cooling units. Temperature sensors in room thermostats are highly sensitive and may require calibration to match other thermometers in the living space. You can reset your room thermostat to its default factory settings, which resets mode temperature values and calibration settings. There are 2 modes in the room thermostat: Comfort Mode and Economy Mode, which work according to pre-set temperature values adjusted by the user. To change the comfort mode temperature value, press and hold the comfort mode button for 3 seconds. Press the On/Off button until the menu appears to access various settings. Recommended temperature calibration is 0.0°C.
- Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. Devices are delivered in working condition, and on-site commissioning incurs a service fee. Repairs under warranty must be conducted at the company's factory, and transportation costs for on-site services are the customer's responsibility. Maintenance is also handled by the company, with travel expenses borne by the customer. Malfunctions during the warranty period are assessed to determine if they are due to customer or manufacturer faults. Manufacturer-induced errors allow for repair or replacement at no cost, while customer-caused faults incur all expenses. Customers must report any product damages to maintain warranty rights. Malfunctions from improper use are not covered by the warranty. Devices are out of warranty if damaged by the customer or if used with unauthorized brands. Battery leakage and damages from environmental factors are also excluded from warranty coverage.