ROOM THERMOSTAT PLACEMENT  
WIRING DIAGRAM FOR ACTUATOR  
ENGLISH  
Place your Room Thermostat in a room you use frequently in your  
living space. For example; like the hall or living room of your home.  
Avoid installing the Room Thermostat in places where there is a lot of  
air circulation, such as at the doorway or by the window. Also, do not  
place it close to heating units (heater core, fireplace, etc.) and in direct  
sunlight. We recommend that the room thermostat is placed at a  
height of 150cmfrom theoor.  
N
L
L1  
N1  
UNDERFLOOR HEATING THERMOSTAT  
generallife.com.tr  
FH104S USER MANUAL  
min. 20 cm  
GENERAL SPECIFICATIONS  
UNDERFLOOR HEATING THERMOSTAT  
FH104S is a floor heating room thermostat. User provides more  
comfortable and affordable heating by setting needed room  
temperature.  
SensitiveTemperatureMeasurement  
Wired Connection  
ACTUATOR  
ON/ OFFControl  
ROOM THERMOSTAT WORKING PRINCIPLE  
FH104S  
USER MANUAL  
As soon as you energize your Room Thermostat, it will start working.  
Your Room Thermostat measures the temperature of the  
environment it is in every 5 seconds. If the ambient temperature rises  
0.5 degrees above the temperature you set, your Room Thermostat  
turns off the heating unit, and if it falls below 0.5 degrees, it turns on  
theheating unit.  
FH104S AND EQUIPMENTS  
230V AC  
FH104S Room Thermostat  
Dowels and  
Screws  
WIRING DIAGRAM FOR WIRING CENTER  
If the floor sensor measures temperature above 28°C, it turns off the  
heating unit. The floor sensor operating sensitivityis ±1°C.*  
Thus, it is ensured that the ambient temperature remains within a  
certain range.  
N
L
L1  
N1  
*Externaloor sensor is only activewhen itis connected.  
TECHNICAL DATA  
Note: If a floor sensor is installed with Room Thermostat, only  
GENERAL Life floor sensor should be installed. Otherwise, the  
product willbe out of warranty.  
Dimensions ( H / L / W )  
Operating Current  
Relay NO Switching Current  
85.7mm / 85.7mm / 33.5mm  
230V AC  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
0.1oC  
ROOM THERMOSTAT WIRING DIAGRAM  
Temperature Measurement  
Accuracy  
0.5oC  
1
2
3
4
Operating Temperature Range  
Operating Temperature  
Storage Temperature  
(5oC) – (30oC)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
WIRING  
CENTER  
ROOM THERMOSTAT  
230V AC  
Indicator LED  
Set Button  
WARNING!  
Operations related to the control panel, heating unit or electrical  
installation must be carried out by persons with professional  
qualifications.  
5
N
L
NTC  
L1  
N1  
WARNING!  
6
RoomThermostatIndicator LED Descriptions  
LED light is on  
LED light is off  
Heating unit is working  
The assembly of product  
Heating unit is not working  
should be done according to  
the image above.  
For electrical connection,  
please see diagram 5.  
Should not be used in case  
the usage of a wiring center.  
generallife.com.tr  
1
2
3
GeneralDetails
NameGENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size1.97 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE HT25 RF Wireless Room Thermostat User Manual
GENERAL LIFE HT25 RF Wireless Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual Overview

Summary of Contents

  • Page 1: Room thermostat placement should be in frequently used rooms, avoiding areas with high air circulation or direct sunlight. The recommended height for the room thermostat installation is 150 cm from the floor. The FH104S is a floor heating room thermostat that allows users to set the desired room temperature for comfort and affordability. The room thermostat measures the ambient temperature every 5 seconds and controls the heating unit based on a 0.5-degree threshold. If the floor sensor measures above 28°C, it will turn off the heating unit, maintaining a specific temperature range. Only the General Life floor sensor should be used with the room thermostat to maintain warranty validity. The operating temperature range for the room thermostat is from 5°C to 30°C. Professional qualifications are required for operations related to the control panel, heating unit, or electrical installation. The indicator LED on the room thermostat shows whether the heating unit is working or not. The assembly of the product should follow the provided diagrams for proper installation.
  • Page 2: warranty certificate declaration of conformity devices and their apparatus are out of warranty if they are beaten, broken or scratched by the customer. damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty. battery leakage and errors due to rust, oxidation and liquid contact by working in acidic/humid environments are not covered by the warranty. damages that may occur during the transportation of devices and apparatus are not covered by the warranty. the warranty period starts from the invoice date and is warranted against manufacturing defects for 2 years. the repair of the devices and apparatus covered by the warranty is carried out in our company factory. the customer can make complaints and appeals to consumer courts or consumer arbitration committees. the warranty document must be kept by the customer during the warranty period.