WEINMANN C16 WiFi Digital Room Thermostat Instruction Manual
Standard program for home use:
Home
7. WiFi Connection (C16 WiFi version only)
Step 1: Download the App via the QR code or by
searching for “Warmme” in the App Store or Google Play
store.
Start
period 1
End
period 1
Start
period 2
End
period 2
06:00
20.0oC
08:30
15.0oC
17:00
20.0oC
23:00
15.0oC
Step 2: Start the App and create or log in with an existing
Mon - Fri
Sat - Sun
account.
06:00
20.0oC
08:30
20.0oC
17:00
20.0oC
23:00
15.0oC
Step 3: On thermostat: Simultaneously press and for
Step 4: Click on “Add device” at the bottom of the screen.
Step 5:
Start
work day
End
work day
Step 6: Click “Done” after the App has connected to the thermostat and the
07:00
20.0oC
18:00
15.0oC
connection is complete.
Mon - Fri
Sat - Sun
Step 7: You can check, adjust or set the current temperature, turn the thermostat on
07:00
20.0oC
18:00
15.0oC
8.4.3 Consumption (READ)
You can use the App to give other people in your family access to or exclude multiple
thermostats.
Displays the warm-up time (in percent) within a given period (1.30 or 365 days). In
MENU, press or to select READ.
Google Assistant or Amazon Alexa
Press o to view the previous day’s consumption. Press or to display the
consumption of 1 day, 30 days or 365 days.
Via a Google or Amazon supported speaker you can set the temperature of your
thermostat higher or lower or ask what the current temperature is. Connecting to
Google Assistant or Amazon Alexa is explained in the App. In the App, go to your
Example:
The consumption is 20% and the installed power 300 Watt
20% x 300Watt = 60 Watt consumption per hour.
60W x 24 hours = 1.440 Watt consumption per day.
8. Function and operation
Press to return to the main menu.
8.1 Temporary temperature
On the main screen, press or to set the temporary temperature. This temporary
temperature is active until the start of the next heating period.
8.4.4 Advanced Settings (SET)
PLEASE NOTE: Settings in this menu may only be adjusted in consultation with the
supplier/installer to prevent unwanted results.
In MENU, press or to select SET.
8.2 Mode
On the main screen, press to select the following modes:
1.
2.
3.
4.
5.
6.
7.
Sensor selection
Room temp. calibration
Smart mode: This is the default mode. The thermostat operates on the basis
Floor temperature calibration
of the set heating schedule in order to save energy.
Floor temperature limit
Schedule selection
Manual mode: Thermostat operates on the basis of the manually set
Used for heating or cooling
temperature.
Intelligent function. This function ensures that the requested temperature has
already been reached when the period starts.
Frost protection mode: The thermostat will operate with the low set
temperature. The maximum is 15oC.
8.
9.
Reset to factory settings
Each setting can be adjusted via or
Full schedule:
.
8.3 Key lock
Lock all keys to prevent settings from being changed. On the main screen,
press and simultaneously for 3 seconds to lock or unlock.
No. Function
Default setting
Options
00: Floor sensor
01: Room sensor
8.4 Menu
On the main screen press and hold for 3 seconds to activate the menu.
1.
Sensor selection
00: Floor sensor
03: External room sensor
CLK
Set day and time (8.4.1)
Set schedule (8.4.2)
2.
3.
4.
Room temperature calibration 0.0oC
-5.0oC - 5.0oC
-5.0oC - 5.0oC
20.0oC - 50.0oC
EVE
READ
SET
Read consumption in % (8.4.3)
Advanced settings (8.4.4)
Return to main screen
Floor temperature calibration 0.0oC
35.0oC
END
00: 7 days
01: Mon to Fri + Sat + Sun
5.
6.
7.
8.
9.
Schedule
00: 7 days
8.4.1 Clock (CLK)
Day, hour and minutes can be adjusted here via or
With the WiFi version it is automatically updated after connection.
.
00: Heating
01: Cooling (only for water based systems)
Used for
00: Heating
00: On
00: On
Intelligent function
Location
8.4.2 Programming periods (EVE)
In MENU, press or to select EVE. The standard program can be adjusted on the
thermostat via or .
00: Home
00: Home
00: No
00: No
01: Reset
Reset
•
•
First choose the day via or (This can be done per day or as a cluster
monday to friday and saturday/sunday separately).
Then choose an event:
8.5 Open window detection
Awake
Departure
Return
Sleep
automatically for 15 minutes when it detects a rapid drop in temperature.
•
•
Next step is to set the (start or end time).
desired temperature and the lowering temperature may be approx. 3oC as main
heating and max. 5oC as auxiliary heating.
9. Error messages
E1: Room sensor fault
E2: Floor sensor fault
Repeat this until all periods and days have been programmed. If you have a WiFi
thermostat, you can do this easily via the App.
E3: Sensor error external sensor