Home > WEINMANN > WEINMANN C16 WiFi Digital Room Thermostat Instruction Manual

WEINMANN C16 WiFi Digital Room Thermostat Instruction Manual

Standard program for home use:  
Home  
7. WiFi Connection (C16 WiFi version only)  
Step 1: Download the App via the QR code or by  
searching for “Warmme” in the App Store or Google Play  
store.  
Start  
period 1  
End  
period 1  
Start  
period 2  
End  
period 2  
06:00  
20.0oC  
08:30  
15.0oC  
17:00  
20.0oC  
23:00  
15.0oC  
Step 2: Start the App and create or log in with an existing  
Mon - Fri  
Sat - Sun  
account.  
06:00  
20.0oC  
08:30  
20.0oC  
17:00  
20.0oC  
23:00  
15.0oC  
Step 3: On thermostat: Simultaneously press and for  
Step 4: Click on “Add device” at the bottom of the screen.  
Step 5:  
Start  
work day  
End  
work day  
Step 6: Click “Done” after the App has connected to the thermostat and the  
07:00  
20.0oC  
18:00  
15.0oC  
connection is complete.  
Mon - Fri  
Sat - Sun  
Step 7: You can check, adjust or set the current temperature, turn the thermostat on  
07:00  
20.0oC  
18:00  
15.0oC  
8.4.3 Consumption (READ)  
You can use the App to give other people in your family access to or exclude multiple  
thermostats.  
Displays the warm-up time (in percent) within a given period (1.30 or 365 days). In  
MENU, press or to select READ.  
Google Assistant or Amazon Alexa  
Press o to view the previous day’s consumption. Press or to display the  
consumption of 1 day, 30 days or 365 days.  
Via a Google or Amazon supported speaker you can set the temperature of your  
thermostat higher or lower or ask what the current temperature is. Connecting to  
Google Assistant or Amazon Alexa is explained in the App. In the App, go to your  
Example:  
The consumption is 20% and the installed power 300 Watt  
20% x 300Watt = 60 Watt consumption per hour.  
60W x 24 hours = 1.440 Watt consumption per day.  
8. Function and operation  
Press to return to the main menu.  
8.1 Temporary temperature  
On the main screen, press or to set the temporary temperature. This temporary  
temperature is active until the start of the next heating period.  
8.4.4 Advanced Settings (SET)  
PLEASE NOTE: Settings in this menu may only be adjusted in consultation with the  
supplier/installer to prevent unwanted results.  
In MENU, press or to select SET.  
8.2 Mode  
On the main screen, press to select the following modes:  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
Sensor selection  
Room temp. calibration  
Smart mode: This is the default mode. The thermostat operates on the basis  
Floor temperature calibration  
of the set heating schedule in order to save energy.  
Floor temperature limit  
Schedule selection  
Manual mode: Thermostat operates on the basis of the manually set  
Used for heating or cooling  
temperature.  
Intelligent function. This function ensures that the requested temperature has  
already been reached when the period starts.  
Frost protection mode: The thermostat will operate with the low set  
temperature. The maximum is 15oC.  
8.  
9.  
Reset to factory settings  
Each setting can be adjusted via or   
Full schedule:  
.  
8.3 Key lock  
Lock all keys to prevent settings from being changed. On the main screen,  
press and simultaneously for 3 seconds to lock or unlock.  
No. Function  
Default setting  
Options  
00: Floor sensor  
01: Room sensor  
8.4 Menu  
On the main screen press and hold for 3 seconds to activate the menu.  
1.  
Sensor selection  
00: Floor sensor  
03: External room sensor  
CLK  
Set day and time (8.4.1)  
Set schedule (8.4.2)  
2.  
3.  
4.  
Room temperature calibration 0.0oC  
-5.0oC - 5.0oC  
-5.0oC - 5.0oC  
20.0oC - 50.0oC  
EVE  
READ  
SET  
Read consumption in % (8.4.3)  
Advanced settings (8.4.4)  
Return to main screen  
Floor temperature calibration 0.0oC  
35.0oC  
END  
00: 7 days  
01: Mon to Fri + Sat + Sun  
5.  
6.  
7.  
8.  
9.  
Schedule  
00: 7 days  
8.4.1 Clock (CLK)  
Day, hour and minutes can be adjusted here via or   
With the WiFi version it is automatically updated after connection.  
.  
00: Heating  
01: Cooling (only for water based systems)  
Used for  
00: Heating  
00: On  
00: On  
Intelligent function  
Location  
8.4.2 Programming periods (EVE)  
In MENU, press or to select EVE. The standard program can be adjusted on the  
thermostat via or .  
00: Home  
00: Home  
00: No  
00: No  
01: Reset  
Reset  
First choose the day via or (This can be done per day or as a cluster  
monday to friday and saturday/sunday separately).  
Then choose an event:  
8.5 Open window detection  
Awake  
Departure  
Return  
Sleep  
automatically for 15 minutes when it detects a rapid drop in temperature.  
Next step is to set the (start or end time).  
desired temperature and the lowering temperature may be approx. 3oC as main  
heating and max. 5oC as auxiliary heating.  
9. Error messages  
E1: Room sensor fault  
E2: Floor sensor fault  
Repeat this until all periods and days have been programmed. If you have a WiFi  
thermostat, you can do this easily via the App.  
E3: Sensor error external sensor  
GeneralDetails
NameWEINMANN C16 WiFi Digital Room Thermostat Instruction Manual
MakeWEINMANN
LanguageEnglish
FiletypePDF (Download)
File size0.42 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

WEINMANN C16 WiFi Digital Room Thermostat Instruction Manual