Home > sinop > sinop TH1134ZB Smart Line Voltage Thermostat Installation Guide

sinop TH1134ZB Smart Line Voltage Thermostat Installation Guide

YOUR TH1134ZB/HC THERMOSTAT  
TECHNICAL SPECIFICATIONS  
Operatlng voltage: 120 / 208 / 240 Vac, 60 Hz  
TH1134ZB/HC Thermostat  
Maximum load:  
16.7 A / 2000 W @ 120 Vac  
16.7 A / 4000 W @ 240 Vac  
Resistive load only.  
Full-color display  
Minimum load:  
1.25 A / 300 W @ 240 Vca  
1.25 A / 150 W @ 120 Vca  
Cooling setpoint range: 61°F to 86°F (16°C to 30°C)  
Heating setpoint range: 41°F to 86°F (5°C to 30°C)  
Display range: 32°F to 99°F (0°C to 50°C)  
Storage: -4°F to 122°F (-20°C to 50°C)  
Operation: 32°F to 122°F (0°C to 50°C)  
Resolution: 0.5°C ( 1°F)  
TH1134ZB/HC  
Installation Guide  
Touch-sensor  
buttons  
Smart Line Voltage Thermostat  
Protocol: Zigbee 3.0  
Frequency: 2.4 GHz  
Transmission power: +20 dBm  
Receiver sensitivity: -108 dBm  
Compatible with an electric heating system such as:  
• Baseboard heater [short cycle]  
• Convector [short cycle]  
Touch control  
• Fan-forced convector [long cycle)  
• Radiant ceiling heating  
• Ductless air conditioners and heat pumps  
units with the HP6000ZB series controller*  
* Scan the QR code to view the list  
of compatible devices or visit  
Warnings  
Special CO/ ALR solderless connectors must be used  
when connecting with aluminum conductors.  
The installation of this thermostat must be performed by a certified electrician  
and comply with the national and local electrical codes and regulations.  
INSTALL YOUR THERMOSTAT  
Use the connectors provided to connect the thermostat wires to the wires in the  
electrical box. Use the screws to secure the thermostat to the electrical box.  
3
Unlock and lift the  
thermostat cover.  
1
Make sure that the  
breakers for your  
heating system are  
off at the main  
2
electrical panel.  
Three-wire installation  
Electrical  
Make sure to firmly tighten the  
wire connectors for a secure  
connection. A loose connection  
can be a fire hazard.  
panel  
L2  
N/L1  
3/4"  
To install wire connectors,  
you must:  
White - Neutral/Line 1  
Insert the two wires into the wire nut so that their  
copper ends are parallel.  
1
Red - Load  
Black - Line 2  
2
3
Turn the wire connector clockwise until there is  
strong tension.  
Replace the cover  
and lock.  
Power up the thermostat.  
5
4
Pull on the threads to make sure they are secure,  
leaving no gaps between them. * If the threads  
seem to come loose, repeat the process.  
* Improperly installed electrical wires could burn the wire  
connectors.  
To control a ductless air conditioner and heat pump unit, you  
will need to install an HP6000ZB series controller.  
GeneralDetails
Namesinop TH1134ZB Smart Line Voltage Thermostat Installation Guide
Makesinop
LanguageEnglish
FiletypePDF (Download)
File size0.56 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
sinop TH1500ZB Smart Double Pole Thermostat User Guide
sinop TH1500ZB Smart Double Pole Thermostat User Guide

sinop TH1134ZB Smart Line Voltage Thermostat Installation Guide
Get the free PDF manual for the sinop TH1134ZB Smart Line Voltage Thermostat Installation Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

sinop TH1134ZB Smart Line Voltage Thermostat Installation Guide Overview

Summary of Contents

  • Page 1: YOUR TH1134ZB/HC THERMOSTAT Technical specifications include operating voltage of 120 / 208 / 240 Vac, 60 Hz. Maximum load is 16.7 A / 2000 W @ 120 Vac and 16.7 A / 4000 W @ 240 Vac. Cooling setpoint range is 61°F to 86°F (16°C to 30°C) and heating setpoint range is 41°F to 86°F (5°C to 30°C). Display range is 32°F to 99°F (0°C to 50°C) with a resolution of 0.5°C (1°F). Installation guide emphasizes that installation must be performed by a certified electrician. Warnings state that special CO/ALR solderless connectors must be used with aluminum conductors. Ensure breakers for the heating system are off at the main electrical panel before installation. Use provided connectors to connect thermostat wires securely to the electrical box. Improperly installed electrical wires could burn the wire connectors. To control a ductless air conditioner and heat pump unit, an HP6000ZB series controller is required.
  • Page 2: Add your thermostat to the GT130 gateway and Neviweb. Connect your thermostat to the network by pressing briefly and simultaneously on the buttons. Initiate the connectivity session by pressing the RF signal button on the GT130 gateway. If you do not have an account yet, download the Neviweb app for iOS or Android to create an account and add your device. Once the connection is complete, a connection confirmation will appear on the screen. To disconnect your thermostat from the GT130 gateway or a compatible Zigbee hub, press the button for 5 seconds. To customize the settings in the configuration menu, you must access the configuration menu. This equipment has been tested and found to comply with the limits for a Class B digital device. Sinopé Technologies Inc. warrants the components of their products against defects in material and workmanship for a 3-year period from the date of purchase. Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United States.